Nissan Qashqai (2007-2010). Manual — part 947
![](/vehicle/qul/ene/roryboritele/wofr.png)
HAC-148
< COMPONENT DIAGNOSIS >
[MANUAL AIR CONDITIONER]
HIGH-LEVEL VENTILATOR DOOR MOTOR
2.
Turn ignition switch ON.
3.
Check voltage between heater control panel harness connector M54 terminal 1 and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 6.
3.
CHECK GROUND CIRCUIT FOR HEATER CONTROL PANEL
1.
Turn ignition switch OFF.
2.
Check continuity between heater control panel harness connector M54 terminal 20 and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair harness or connector.
4.
CHECK POWER SUPPLY FOR HIGH-LEVEL VENTILATOR DOOR MOTOR
1.
Reconnect heater control panel connector.
2.
Turn ignition switch ON.
3.
Check voltage between high-level ventilator door motor harness connector M43 terminal 1 and 2.
Is the inspection result normal?
YES
>> Replace high-level ventilator door motor.
NO
>> GO TO 5.
5.
CHECK CIRCUIT CONTINUITY BETWEEN HEATER CONTROL PANEL AND HIGH-LEVEL VENTILATOR
DOOR MOTOR
1.
Turn ignition switch OFF.
2.
Disconnect heater control panel connector and high-level ventilator door motor connector.
3.
Check continuity between heater control panel harness connector M54 terminal 13 and high-level ventila-
tor door motor harness connector M43 terminal 1.
4.
Check continuity between heater control panel harness connector M54 terminal 14 and high-level ventila-
tor door motor harness connector M43 terminal 2.
Is the inspection result normal?
YES
>> Replace heater control panel.
(+)
(
−
)
Voltage
Heater control panel
—
Connector
Terminal
M54
1
Ground
Battery voltage
Heater control panel
—
Continuity
Connector
Terminal
M54
20
Ground
Continuity should exist
(+)
(
−
)
Condition
Voltage
High-level ventilator door motor
Connector
Terminal
Connector
Terminal
M43
1
M43
2
High-level ventilator
SW: ON
Approx. 12
2
1
High-level ventilator
SW: OFF
Heater control panel
High-level ventilator door motor
Continuity
Connector
Terminal
Connector
Terminal
M54
13
M43
1
Continuity should exist
14
2
![](/vehicle/qul/ene/roryboritele/sola.png)
HIGH-LEVEL VENTILATOR DOOR MOTOR
HAC-149
< COMPONENT DIAGNOSIS >
[MANUAL AIR CONDITIONER]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
NO
>> Repair harness or connector.
6.
CHECK FUSE
Check 10A fuse [No.4 located in the fuse block (J/B)]. Refer to
PG-110, "Fuse, Connector and Terminal
.
Is the inspection result normal?
YES
>> Repair harness or connector.
NO
>> Replace fuse.
Component Inspection
INFOID:0000000001117102
HIGH-LEVEL VENTILATOR SWITCH
Check continuity between high-level ventilator switch (1) M52 termi-
nal 2and 3.
JSIIA0304ZZ
High-level ventilator switch
Condition
Continuity
Connector
Terminal
Connector
Terminal
M52
2
M52
3
High-level VENT SW: OFF
Continuity should not exist
High-level VENT SW: ON
Continuity should exist
![](/vehicle/qul/ene/roryboritele/opiazatrh.png)
HAC-150
< COMPONENT DIAGNOSIS >
[MANUAL AIR CONDITIONER]
INTAKE DOOR MOTOR
INTAKE DOOR MOTOR
Description
INFOID:0000000001069965
COMPONENT DESCRIPTION
Intake Door Motor
The intake door motor (1) is attached to the A/C unit assembly. It
rotates so that air is drawn from inlets set by the heater control
panel. Motor rotation is conveyed to a lever which activates the
intake door.
Component Function Check
INFOID:0000000001069966
1.
CONFIRM SYMPTOM BY PERFORMING THE FOLLOWING OPERATIONAL CHECK
1.
Press REC switch.
2.
REC indicator should illuminate.
3.
Listen for intake door position change. (Slight change of blower sound can be heard.)
4.
Press REC switch again.
5.
REC indicator should not illuminate.
Is the inspection result normal?
YES
>> END.
NO
>> Go to diagnosis procedure. Refer to
HAC-150, "Diagnosis Procedure"
Diagnosis Procedure
INFOID:0000000001069967
1.
CHECK INTAKE DOOR CONTROL LINKAGE
Check intake door control linkage.
Is it installed normally?
YES
>> GO TO 2.
NO
>> Repair or adjust control linkage.
2.
CHECK POWER SUPPLY FOR HEATER CONTROL PANEL
1.
Disconnect heater control panel connector.
2.
Turn ignition switch ON.
3.
Check voltage between heater control panel harness connector M54 terminal 1 and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 6.
3.
CHECK GROUND CIRCUIT FOR HEATER CONTROL PANEL
1.
Turn ignition switch OFF.
2.
Check continuity between heater control panel harness connector M54 terminal 20 and ground.
JPIIA0027ZZ
(+)
(
−
)
Voltage
Heater control panel
—
Connector
Terminal
M54
1
Ground
Battery voltage
![](/vehicle/qul/ene/roryboritele/yon.png)
INTAKE DOOR MOTOR
HAC-151
< COMPONENT DIAGNOSIS >
[MANUAL AIR CONDITIONER]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair harness or connector.
4.
CHECK POWER SUPPLY FOR INTAKE DOOR MOTOR
1.
Reconnect heater control panel connector.
2.
Turn ignition switch ON.
3.
Check voltage between intake door motor harness connector M68 (LHD models) or M303 (RHD models)
terminal 1 and 2.
LHD models
RHD models
Is the inspection result normal?
YES
>> Replace intake door motor.
NO
>> GO TO 5.
5.
CHECK CIRCUIT CONTINUITY BETWEEN HEATER CONTROL PANEL AND INTAKE DOOR MOTOR
1.
Turn ignition switch OFF.
2.
Disconnect heater control panel connector and intake door motor connector.
3.
Check continuity between heater control panel harness connector M54 terminal 10 and intake door motor
harness connector M68 terminal 1 (LHD models) or M303 terminal 1 (RHD models).
4.
Check continuity between heater control panel harness connector M54 terminal 11 and intake door motor
harness connector M68 terminal 2 (LHD models) or M303 terminal 2 (RHD models).
LHD models
RHD models
Is the inspection result normal?
YES
>> Replace heater control panel.
NO
>> Repair harness or connector.
Heater control panel
—
Continuity
Connector
Terminal
M54
20
Ground
Continuity should exist
(+)
(
−
)
Condition
Voltage
Intake door motor
Connector
Terminal
Connector
Terminal
M68
2
M68
1
REC SW: ON
Approx. 12
1
2
REC SW: OFF
(+)
(
−
)
Condition
Voltage
Intake door motor
Connector
Terminal
Connector
Terminal
M303
2
M303
1
REC SW: ON
Approx. 12
1
2
REC SW: OFF
Heater control panel
Intake door motor
Continuity
Connector
Terminal
Connector
Terminal
M54
10
M68
1
Continuity should exist
11
2
Heater control panel
Intake door motor
Continuity
Connector
Terminal
Connector
Terminal
M54
10
M303
1
Continuity should exist
11
2
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.