Subaru Impreza 3 / Impreza WRX / Impreza WRX STI. Service manual — part 778
LAN(diag)-21
Subaru Select Monitor
LAN SYSTEM (DIAGNOSTICS)
8) Change the setting with UP/DOWN key.
• List of body integrated unit registration item
NOTE:
Setting is different depending on the grade of vehicle.
CAUTION:
• To perform normal operation of vehicle and diagnosis, the above settings must match the actual
vehicle equipment.
• When body integrated unit is a new part or “Factory” mode, key illumination blinks to show
equipment settings have not been completed. Check the detailed procedures of User Customizing.
• Be sure not to change Factory initial setting except when installing a new body integrated unit.
NOTE:
“Factory” mode:
• Body integrated unit has not been set yet. It can be recognized by key illumination blinking with ignition
switch turned to ON.
• All replacement body integrated units are set to “Factory” mode. When replacing a body integrated unit,
be sure to perform the registration operation.
“Market” mode:
• Each settings have been set. It can be recognized by key ring illumination coming on in concocting with
room light and going off with ignition switch turned to ON.
9) Perform the Factory initial setting. On the «Unit customizing» display screen of Subaru Select Monitor, se-
lect the {Factory initial setting}.
10) Change the mode from Factory to Market and then turn the ignition switch to OFF.
11) Change the Subaru Select Monitor system selection to «Immobilizer» to register the immobilizer key.
(model with immobilizer)
12) Perform the registration according to the procedures of the “REGISTRATION MANUAL FOR IMMOBI-
LIZER”.
13) When key registration is completed, “Do you want to register remote engine start?” is displayed. Perform
registration only for equipped models.
14) Perform the User Customizing.
<Ref. to LAN(diag)-23, USER CUSTOMIZING, OPERATION, Subaru Select Monitor.>
NOTE:
For detailed operation procedures, refer to “PC application help for Subaru Select Monitor”.
Data
Initial setting
Registration
Remarks
Map lamp 30 sec off record
OFF
ON
Set to “OFF” for models with door interlock switch in map light,
“ON” for models without door interlock switch.
OFF
A/C ECM setting
OFF
ON
Set to “ON” in case of model with auto A/C. Set to “OFF” in case
of model without auto A/C.
OFF
wiperdeicer (factory option)
OFF
ON
Be sure to set exactly according to vehicle equipment. ON sig-
nal does not output with switch operation when it is set to “OFF”.
OFF
Sedan/Wagon Setting
Wagon
Sedan
Be sure to set exactly according to vehicle model. This relates
to door lock control.
Wagon
MT/AT Setting
AT
MT
Be sure to set exactly according to vehicle model. This relates
to key interlock control, shift lock control.
AT
6MT Setting
Other than
6MT
6MT
Set “6MT” for 6MT model, and set “Other than 6MT” for AT/5AT
model.
Other than 6MT
Factory initial setting
Factory
Factory
Be sure to set to “Market”. After setting change, turn the ignition
switch to OFF and settle the changed settings.
Market
LAN(diag)-22
Subaru Select Monitor
LAN SYSTEM (DIAGNOSTICS)
6. CLEAR MEMORY MODE
1) On «Main Menu» display, select {Each System Check}.
2) On «System Selection Menu» display, select {Integ. unit mode}.
3) Press the [OK] key after the information of body integrated unit type is displayed.
4) On «Integ. unit mode failure diag» display, select {Clear Memory} and press the [OK] key.
5) When “Done” is shown on the display screen, turn the ignition switch to OFF.
NOTE:
For details concerning the operation procedure, refer to “PC application help for Subaru Select Monitor”.
7. FREEZE FRAME DATA
NOTE:
• Data stored at the time of trouble occurrence is shown on display.
• Freeze frame data will be memorized maximum to 20.
• If freeze frame data is not stored in memory correctly (caused by low power supply of body integrated unit),
DTC will be displayed with “?” on the head of it in the Subaru Select Monitor display. This shows it may be
an unreliable reading.
Display
Contents to be displayed
Clear Memory ?
Clear function of DTC and
freeze frame data
LAN(diag)-23
Subaru Select Monitor
LAN SYSTEM (DIAGNOSTICS)
8. USER CUSTOMIZING
1) On «Main Menu» display, select {Each System Check}.
2) On «System Selection Menu» display, select {Integ. unit mode}.
3) On «Integ. unit mode failure diag.» display, select {Integ. Unit customizing}.
4) Change the setting with UP/DOWN key and set with the [OK] key.
• List of User Customizing item
Data
Initial setting
value
Customize
setting
Remarks
Off delay time
Long
Delay time below can be selected by setting.
OFF
0 seconds
Short
10 seconds
Normal
20 seconds
Long
30 seconds
Rr Defogger op. mode
15 minutes
15 minutes
Automatically stops in 15 minutes after switch is turned to ON.
Continuous
Repeats active condition for 15 minutes and inactive condition for 2
minutes until switch is turned to OFF.
Security Alarm Setup
ON
ON
Security alarm (hazard, horn or siren) in active condition
OFF
Security alarm in inactive condition
Impact Sensor Setup
OFF
ON
Workable when Impact Sensor Setup is set to “ON” Impact sensor
function becomes activated.
OFF
Impact sensor in inactive condition (Set to “OFF” in models without
sensors.)
Alarm delay setup
ON
After the keyless lock operation, the alarm monitor starts after the
following delay time has passed.
ON
Delay time is 30 seconds.
OFF
Delay time is 0 seconds.
Lockout prevention
ON
ON
Lockout prevention in active condition. (The function does not oper-
ate if safety knob is locked by hand.)
OFF
Lockout prevention in inactive condition
Impact sensor (OP)
OFF
ON
Workable when Impact Sensor Setup is set to “ON” Impact sensor
function becomes activated.
OFF
Impact sensor in inactive condition (Set to “OFF” in models without
sensors.)
Buzzer beeping setup
ON
ON
Workable when Buzzer setting is “ON”.
When lock/unlock is selected by keyless entry system operation,
buzzer operates.
OFF
When lock/unlock is selected by keyless entry system operation,
buzzer does not operate.
Emergency light setup
ON
ON
When lock/unlock is selected by keyless entry system operation,
buzzer operates.
OFF
When lock/unlock is selected by keyless entry system operation,
buzzer does not operate.
Buzzer setting
ON
ON
Vehicle is controlled in answer-back buzzer equipped mode.
OFF
Vehicle is controlled in answer-back buzzer non-equipped mode.
(Make sure to set to “OFF” in models without answer back buzzers.)
Initial keyless setting
—
—
Execution
Settings of keyless entry system are initialized.
Initial button setting
—
—
Execution
Settings of each function are initialized.
Passive Alarm
OFF
ON
Setting only for North American models
OFF
LAN(diag)-24
Subaru Select Monitor
LAN SYSTEM (DIAGNOSTICS)
5) After setting, make sure that the setting changed in the {Current Data Display & Save} is same as vehicle
equipment.
CAUTION:
• The above settings must match the actual vehicle equipment.
• Do not change settings except for above setting while performing the User Customizing.
• Be sure not to change Factory initial setting except when installing a new body integrated unit.
NOTE:
For detailed operation procedures, refer to “PC application help for Subaru Select Monitor”.
9. FUNCTION CHECK
In order to check the body integrated unit function, inspect the body integrated unit and actuator using Sub-
aru Select Monitor without operating switches.
1) On «Main Menu» display, select {Each System Check}.
2) On «System Selection Menu» display, select {Integ. unit mode}.
3) On «Integ. unit mode failure diag.» display, select {Function check}.
4) Select the item to be operated on the «Function check» display screen with “UP/Down key” and press the
[Next] button.
5) Pressing [Next] starts, [End] cancels the operation and [OK] returns to the System Operation Check Mode
display screen.
NOTE:
If not equipped (based on area or condition), process will not go on.
Door open warning
ON
ON
If detecting door open for 20 minutes, room light, map light, and key
ring illumination that are related to doors are turned off to prevent
battery run-out.
OFF
Room light, map light, key illumination and door warning light are
not turned off.
Dome Light Alarm Setting
OFF
ON
The room light lights by being interlocked with the activation of the
alarm.
OFF
Map Light Setting
ON
ON
Illuminates in accordance with the door interlocked room light.
(model with sunroof)
OFF
Belt Warning Switch
ON
ON
When using normally
OFF
Stop the belt warning buzzer beep and warning light illumination.
Data
Initial setting
value
Customize
setting
Remarks