Subaru Legacy (2005 year). Service manual — part 262
IN(H4DOTC)-7
INTAKE (INDUCTION)
Air Cleaner Element
2. Air Cleaner Element
A: REMOVAL
1) Disconnect the ground cable from battery.
2) Disconnect the connector (A) from mass air flow
sensor.
3) Loosen the clamps (B) which connect air intake
boot to intake duct.
4) Remove the clips (C) from air cleaner case.
5) Remove the air cleaner case (rear) and air in-
take boot.
6) Remove the air cleaner element.
B: INSTALLATION
Install in the reverse order of removal.
NOTE:
When installing the air cleaner case (rear), align the
protrusion part of air cleaner case (rear) to the hole
of air cleaner case (front).
C: INSPECTION
Replace if excessively damaged or dirty.
IN-00203
IN-00218
(A)
(B)
(C)
(C)
(B)
IN-00220
IN(H4DOTC)-8
Vehicle-id:
SIE-id:S144089a18:A:REMOVAL
∼
INTAKE (INDUCTION)
Air Cleaner Case
3. Air Cleaner Case
A: REMOVAL
1) Remove the air intake duct. <Ref. to
IN(H4DOTC)-9, REMOVAL, Air Intake Duct.>
2) Remove the air cleaner element.
<Ref. to IN(H4DOTC)-7, REMOVAL, Air Cleaner
Element.>
3) Remove the bolts (A) and nut (B) which install air
cleaner case (front) on the body.
4) Remove the air cleaner case (front).
B: INSTALLATION
Install in the reverse order of removal.
Tightening torque:
Bolt: 6.0 N
⋅
m (0.61 kgf-m, 4.4 ft-lb)
Nut: 7.5 N
⋅
m (0.76 kgf-m, 5.5 ft-lb)
C: INSPECTION
Check for cracks or loose connections.
IN-02017
(B)
(A)
IN(H4DOTC)-9
INTAKE (INDUCTION)
Air Intake Duct
4. Air Intake Duct
A: REMOVAL
Remove the clips which install the air intake duct on
the front side of body.
B: INSTALLATION
Install in the reverse order of removal.
C: INSPECTION
1) Check for cracks or loose connection.
2) Inspect that no foreign objects in the air intake
duct.
IN-00217
IN(H4DOTC)-10
Vehicle-id:
SIE-id:S144639a18:A:REMOVAL
∼
INTAKE (INDUCTION)
Resonator Chamber
5. Resonator Chamber
A: REMOVAL
Refer to “Air Cleaner Case” for removal procedure
because the resonator chamber forms a single unit
with air cleaner case. <Ref. to IN(H4DOTC)-8, RE-
MOVAL, Air Cleaner Case.>
B: INSTALLATION
Refer to “Air Cleaner Case” for installation proce-
dure because the resonator chamber forms a sin-
gle unit with air cleaner case. <Ref. to
IN(H4DOTC)-8, INSTALLATION, Air Cleaner
Case.>
C: INSPECTION
Check for cracks or loose connections.