Infiniti M35/M45 Y50. Manual — part 560
![](/vehicles/zatt/cen/houeebante/nolehest.png)
SNOW MODE SWITCH
EC-713
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
9.
CHECK SNOW MODE SWITCH
Refer to
EC-713, "Component Inspection"
OK or NG
OK
>> GO TO 10.
NG
>> Replace snow mode switch.
10.
CHECK INTERMITTENT INCIDENT
Refer to
EC-153, "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT"
>> INSPECTION END
Component Inspection
NBS0058U
SNOW MODE SWITCH
1.
Check continuity between snow mode switch terminals 1 and 4
under the following conditions.
2.
If NG, replace snow mode switch.
If OK, go to following step.
3.
Check continuity between snow mode switch terminals 2 and 4
under the following conditions.
4.
If NG, replace snow mode switch.
CONDITION
CONTINUITY
Snow mode switch: ON
Should exist
Snow mode switch: OFF
Should not exist
PBIB2563E
CONDITION
CONTINUITY
1
Should exist.
2
Should not exist.
PBIB2564E
![](/vehicles/zatt/cen/houeebante/kaspat.png)
EC-714
[VQ35DE]
MIL AND DATA LINK CONNECTOR
MIL AND DATA LINK CONNECTOR
PFP:24814
Wiring Diagram
NBS0058V
TBWT1487E
![](/vehicles/zatt/cen/houeebante/bldanterug.png)
MIL AND DATA LINK CONNECTOR
EC-715
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
TBWT1005E
![](/vehicles/zatt/cen/houeebante/dve.png)
EC-716
[VQ35DE]
SERVICE DATA AND SPECIFICATIONS (SDS)
SERVICE DATA AND SPECIFICATIONS (SDS)
PFP:00030
Fuel Pressure
NBS0058W
Idle Speed and Ignition Timing
NBS0058X
*: Under the following conditions:
●
Air conditioner switch: OFF
●
Electric load: OFF (Lights, heater fan & rear window defogger)
●
Steering wheel: Kept in straight-ahead position
Calculated Load Value
NBS0058Y
Mass Air Flow Sensor
NBS0058Z
*: Engine is warmed up to normal operating temperature and running under no load.
Intake Air Temperature Sensor
NBS00590
Engine Coolant Temperature Sensor
NBS00591
Fuel Tank Temperature Sensor
NBS00592
Crankshaft Position Sensor (POS)
NBS00593
Refer to
EC-370, "Component Inspection"
Camshaft Position Sensor (PHASE)
NBS00594
Refer to
EC-379, "Component Inspection"
A/F Sensor 1 Heater
NBS00595
Fuel pressure at idling kPa (kg/cm
2
, psi)
Approximately 350 (3.57, 51)
Target idle speed
No load* (in P or N position)
650
±
50 rpm
Air conditioner: ON
In P or N position
700 rpm or more
Ignition timing
In P or N position
15
°
±
5
°
BTDC
Condition
Calculated load value% (Using CONSULT-II or GST)
At idle
5.0 - 35.0
At 2,500 rpm
5.0 - 35.0
Supply voltage
Battery voltage (11 - 14V)
Output voltage at idle
0.9 - 1.2V*
Mass air flow (Using CONSULT-II or GST)
2.0 - 6.0 g·m/sec at idle*
7.0 - 20.0 g·m/sec at 2,500 rpm*
Temperature
°
C (
°
F)
Resistance k
Ω
25 (77)
1.800 - 2.200
80 (176)
0.283 - 0.359
Temperature
°
C (
°
F)
Resistance k
Ω
20 (68)
2.1 - 2.9
50 (122)
0.68 - 1.00
90 (194)
0.236 - 0.260
Temperature
°
C (
°
F)
Resistance k
Ω
20 (68)
2.3 - 2.7
50 (122)
0.79 - 0.90
Resistance [at 25
°
C (77
°
F)]
2.3 - 4.3
Ω
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.