Kia Carnival (2007 year). Manual — part 99
Solenoid Valve
2007 > 2.7L V6 GASOLINE >
DESCRIPTION
Actuators
Solenoid Valve for Pressure Control
- Sensor type: Normal open 3-way
- Operating temperature : -30°C~130°C(-22°F~266°F)
- Frequency:
LR, 2ND, UD, OD: 61.27Hz (at the ATF temp. above -20°C(-4°F))
DCC: 30.64Hz
- Internal resistance:
3.0 ± 0.5
Ω (LR, 2ND, UD, OD, TCC)
4.35 ± 0.5
Ω (VFS)
- Surge voltage: 56 V (Except VFS)
(LR, 2ND, UD, OD, DCC)
Location
Solenoid Valves Schedule
Position
Solenoid valves
Operation
LR
2ND
UD
OD
* DCC
1st gear
OFF
ON
OFF
ON
OFF
2nd gear
ON
OFF
OFF
ON
OFF
3rd gear
ON
ON
OFF
OFF
ON
4th gear
ON
OFF
ON
OFF
ON
Reverse
OFF
ON
ON
ON
OFF
N, P (STD. mode)
OFF
ON
ON
ON
OFF
N, P (Hold mode)
ON
OFF
ON
ON
OFF
*: Reference value.
(DCC solenoid valve will be ON when the operating condition is satisfied)
2007 > 2.7L V6 GASOLINE >
INSPECTION
1. If the value is out of specification according to the chart below, remove the valve body cover.
2. Measure the resistance again after disconnecting solenoid valve connector.
Specification (20°C):
2.5 ~ 3.5
Ω (LR, 2ND, UD, OD, TCC)
3. If the value is out of specification replace the solenoid valve.
Pin No.
Name
Resistance
6&9
DCC (TCC)
2.5~3.5
Ω (20°C)
6&11
LR
4&5
2ND
3&5
UD
5&12
OD
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.