Nissan Murano Z51. Instruction — part 574
EC-304
< DTC/CIRCUIT DIAGNOSIS >
[VQ35DE]
P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> GO TO 5.
5.
DETECT MALFUNCTIONING PART
Check the following.
• Harness connectors B4, E104
• Harness for open or short between EVAP control system pressure sensor and ECM
>> Repair open circuit.
6.
CHECK SENSOR POWER SUPPLY CIRCUIT
Check harness for short to power and short to ground, between the following terminals.
Is the inspection result normal?
YES
>> GO TO 7.
NO
>> Repair short to ground or short to power in harness or connectors.
7.
CHECK COMPONENTS
Check the following.
• Crankshaft position sensor (POS) (Refer to
EC-257, "Component Inspection"
• Refrigerant pressure sensor (Refer to
.)
Is the inspection result normal?
YES
>> GO TO 8.
NO
>> Replace malfunctioning components.
8.
CHECK APP SENSOR
EC-409, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 15.
NO
>> GO TO 9.
9.
REPLACE ACCELERATOR PEDAL ASSEMBLY
1.
Replace accelerator pedal assembly.
2.
EC-409, "Special Repair Requirement"
>> INSPECTION END
10.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND
SHORT
1.
Turn ignition switch OFF.
2.
Disconnect ECM harness connector.
3.
Check the continuity between EVAP control system pressure sensor harness connector and ECM har-
ness connector.
EVAP control system pressure sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
B17
3
E16
91
Existed
ECM
Sensor
Connector
Terminal
Name
Connector
Terminal
F8
72
Refrigerant pressure sensor
E300
1
76
CKP sensor (POS)
F20
1
E16
87
APP sensor
E110
5
91
EVAP control system pressure sensor
B17
3
P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR
EC-305
< DTC/CIRCUIT DIAGNOSIS >
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
4.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 12.
NO
>> GO TO 11.
11.
DETECT MALFUNCTIONING PART
Check the following.
• Harness connectors B4, E104
• Harness for open or short between EVAP control system pressure sensor and ECM
>> Repair open circuit, short to ground or short to power in harness or connectors.
12.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND
SHORT
1.
Check the continuity between EVAP control system pressure sensor harness connector and ECM har-
ness connector.
2.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 14.
NO
>> GO TO 13.
13.
DETECT MALFUNCTIONING PART
Check the following.
• Harness connectors B4, E104
• Harness for open or short between EVAP control system pressure sensor and ECM
>> Repair open circuit, short to ground or short to power in harness or connectors.
14.
CHECK RUBBER TUBE
1.
Disconnect rubber tube connected to EVAP canister vent control valve.
2.
Check the rubber tube for clogging.
Is the inspection result normal?
YES
>> GO TO 15.
NO
>> Clean the rubber tube using an air blower, repair or replace rubber tube.
15.
CHECK EVAP CANISTER VENT CONTROL VALVE
EC-288, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 16.
NO
>> Replace EVAP canister vent control valve.
16.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
EC-306, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 17.
NO
>> Replace EVAP control system pressure sensor.
EVAP control system pressure sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
B17
1
E16
96
Existed
EVAP control system pressure sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
B17
2
E16
86
Existed
EC-306
< DTC/CIRCUIT DIAGNOSIS >
[VQ35DE]
P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR
17.
CHECK IF EVAP CANISTER IS SATURATED WITH WATER
1.
Remove EVAP canister with EVAP canister vent control valve and EVAP control system pressure sensor
attached.
2.
Check if water will drain from the EVAP canister.
Does water drain from the EVAP canister?
YES
>> GO TO 18.
NO
>> GO TO 20.
18.
CHECK EVAP CANISTER
Weigh the EVAP canister with the EVAP canister vent control valve and EVAP control system pressure sensor
attached.
The weight should be less than 2.1 kg (4.6 lb).
Is the inspection result normal?
YES
>> GO TO 20.
NO
>> GO TO 19.
19.
DETECT MALFUNCTIONING PART
Check the following.
• EVAP canister for damage
• EVAP hose between EVAP canister and vehicle frame for clogging or poor connection
>> Repair hose or replace EVAP canister.
20.
CHECK INTERMITTENT INCIDENT
GI-39, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000005536697
1.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
1.
Turn ignition switch OFF.
2.
Remove EVAP control system pressure sensor with its harness connector.
Always replace O-ring with a new one.
3.
Install a vacuum pump to EVAP control system pressure sensor.
4.
Turn ignition switch ON and check output voltage between ECM terminals under the following conditions.
CAUTION:
• Always calibrate the vacuum pump gauge when using it.
• Never apply below -93.3 kPa (-0.952 kg/cm
2
, -13.53 psi) or pressure over 101.3 kPa (1.033 kg/cm
2
,
14.69 psi).
Is the inspection result normal?
JMBIA1134GB
ECM
Applied vacuum kPa
(kg/cm
2
, psi)
Voltage
Connector
+
–
Terminal
Terminal
E16
86
(EVAP control system
pressure sensor signal)
96
(Sensor ground)
Not applied
1.8 - 4.8 V
-26.7 (-0.272, -3.87)
2.1 to 2.5 V lower than
above value
P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR
EC-307
< DTC/CIRCUIT DIAGNOSIS >
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
YES
>> INSPECTION END
NO
>> Replace EVAP control system pressure sensor
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.