Subaru Legacy III (2000-2003 year). Service manual — part 241
FU(H6DO)-48
FUEL INJECTION (FUEL SYSTEMS)
FUEL PUMP RELAY
19.Fuel Pump Relay
A: REMOVAL
1) Disconnect battery ground cable.
2) Remove lower cover. <Ref. to EI-35, REMOV-
AL, Instrument Panel Assembly.>
3) Disconnect connector from fuel pump relay.
4) Remove fuel pump relay from mounting bracket.
B: INSTALLATION
Install in the reverse order of removal.
FU-00009
FU-00431
FU(H6DO)-49
FUEL INJECTION (FUEL SYSTEMS)
FUEL PUMP CONTROLLER
20.Fuel Pump Controller
A: REMOVAL
1) Disconnect battery ground cable.
2) Remove rear quarter Trim. <Ref. to EI-40, RE-
MOVAL, Rear Quarter Trim.>
3) Disconnect connector from fuel pump control
unit.
4) Remove fuel pump control unit.
B: INSTALLATION
Install in the reverse order of removal.
FU-00009
FU-00672
FU(H6DO)-50
FUEL INJECTION (FUEL SYSTEMS)
FUEL
21.Fuel
A: OPERATION
1. RELEASING OF FUEL PRESSURE
WARNING:
• Place “NO FIRE” signs near the working area.
• Be careful not to spill fuel on the floor.
1) Disconnect connector from fuel pump relay.
2) Start the engine and run it until it stalls.
3) After the engine stalls, crank it for five more sec-
onds.
4) Turn ignition switch to OFF.
2. DRAINING FUEL
WARNING:
• Place “NO FIRE” signs near the working area.
• Be careful not to spill fuel on the floor.
1) Set vehicle on the lift.
2) Disconnect battery ground cable.
3) Lift-up the vehicle.
4) Remove front right side fuel tank cover.
5) Drain fuel from fuel tank.
Set a container under the vehicle and remove drain
plug from fuel tank.
6) Tighten fuel drain plug and install front right side
tank cover.
Tightening torque:
26 N·m (2.65 kgf-m, 19.2 ft-lb)
Tightening torque:
18 N·m (1.8 kgf-m, 13.0 ft-lb)
7) Lower the vehicle.
FU-00431
FU-00009
FU-00443
FU-00444
FU-00444
FU-00443
FU(H6DO)-51
FUEL INJECTION (FUEL SYSTEMS)
FUEL
8) Remove sub service hole cover.
9) Disconnect connector from fuel sub level sensor.
10) Disconnect fuel jet pump hose.
11) Remove fuel sub level sensor.
12) Drain fuel from fuel tank by using hand pump.
WARNING:
Do not use a motor pump when draining fuel.
13) After draining fuel, reinstall fuel sub level sen-
sor.
Tightening torque:
4.4 N·m (0.45 kgf-m, 3.3 ft-lb)
NOTE:
If you have not removed fuel tank yet, proceed with
the procedure below for installation.
(1) Connect fuel jet pump hose.
(2) Connect connector from fuel sub level sen-
sor.
FU-00445
FU-00446
FU-00447
FU-00448
FU-00448
FU-00447
FU-00446
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.