Isuzu Rodeo UE. Service manual — part 177
6E1–79
RODEO X22SE 2.2L ENGINE DRIVEABILITY AND EMISSION
MALFUNCTION INDICATOR LAMP (MIL) ON STEADY
D06RX039
Circuit Description
The malfunction indicator lamp (MIL) should always be
illuminated and steady with the ignition ON and the
engine stopped. Ignition feed voltage is supplied directly
to the MIL indicator. The powertrain control module
(PCM) turns the MIL ON by grounding the MIL driver
circuit.
The MIL should not remain ON with the engine running
and no DTC(s) set. A steady MIL with the engine running
and no DTC(s) suggests a short to ground in the MIL
driver circuit.
Diagnostic Aids
An intermittent may be caused by a poor connection,
rubbed–through wire insulation, or a wire broken inside
the insulation. Check for the following items:
f
Poor connection or damaged harness – Inspect the
PCM harness and connectors for improper mating,
broken locks, improperly formed or damaged
terminals, poor terminal–to–wire connection, and
damaged harness.
Test Description
Number(s) below refer to the step number(s) on the
Diagnostic Chart:
2. If the MIL does not remain ON when the PCM is
disconnected, the MIL driver wiring is not faulty.
3. If the MIL driver circuit is OK, the instrument panel
cluster is faulty.
6. This vehicle is equipped with a PCM which utilizes
an electrically erasable programmable read only
memory (EEPROM). When the PCM is replaced,
the new PCM must be programmed. Refer to PCM
Replacement and Programming Procedures in
Powertrain Control Module (PCM) and Sensors.
6E1–80
RODEO X22SE 2.2L ENGINE DRIVEABILITY AND EMISSION
Malfunction Indicator Lamp (MIL) ON Steady
Step
Action
Value(s)
Yes
No
1
Was the ”On–Board Diagnostic (OBD) System Check”
performed?
—
Go to Step 2
Go to OBD
System
Check
2
1. Ignition OFF, disconnect the PCM.
2. Ignition ON, observe the MIL (Service Engine Soon
lamp).
Is the MIL ON?
—
Go to Step 3
Go to Step 5
3
1. Ignition OFF, disconnect the instrument panel
cluster.
2. Check the MIL driver circuit between the PCM and
the instrument panel cluster for a short to ground.
3. If a problem is found, repair as necessary.
Was the MIL driver circuit shorted to ground?
—
Go to OBD
System
Check
Go to Step 4
4
Replace the instrument panel cluster.
Is the action complete?
—
Go to OBD
System
Check
—
5
1. Ignition OFF, reconnect the PCM.
2. Ignition ON, reprogram the PCM. Refer to
On–Vehicle Service in Powertrain Control Module
and Sensors for procedures.
3. Using the Tech 2 output controls function, select
MIL dash lamp control and command the MIL OFF.
Did the MIL turn OFF?
—
Go to OBD
System
Check
Go to Step 6
6
Replace the PCM.
IMPORTANT: The replacement PCM must be
programmed. Refer to On–Vehicle Service in
Powertrain Control Module and Sensors for
procedures.
and also refer to latest service bulletin.
Check to see if the Latest software is released or not.
And then Down Load the LATEST PROGRAMMED
SOFTWARE to the replacement PCM.
Is the action complete?
—
Go to OBD
System
Check
—
6E1–81
RODEO X22SE 2.2L ENGINE DRIVEABILITY AND EMISSION
ENGINE CRANKS BUT WILL NOT RUN
D06RX027
6E1–82
RODEO X22SE 2.2L ENGINE DRIVEABILITY AND EMISSION
D06RX029