Infiniti I35 (A33). Manual — part 377
SEF289X
CONSULT-II Inspection Procedure
=NHEL0213
“INT LAMP”/“BATTERY SAVER”
NHEL0213S01
1.
Turn ignition switch “OFF”.
2.
Connect “CONSULT-II” and “CONSULT-II CONVERTER” to
the data link connector.
SKIA3098E
3.
Turn ignition switch “ON”.
4.
Touch “START (NISSAN BASED VHCL)”.
SEL398Y
5.
Touch “SMART ENTRANCE”.
If “SMART ENTRANCE” is not indicated, go to GI-42.
SEL399Y
6.
Touch “INT LAMP” or “BATTERY SAVER”.
SEL400Y
7.
Select diagnosis mode.
“DATA MONITOR”, “ACTIVE TEST” and “WORK SUPPORT”
are available for “INT LAMP” and “BATTERY SAVER”.
GI
MA
EM
LC
EC
FE
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
INTERIOR, STEP, SPOT, VANITY MIRROR AND TRUNK ROOM LAMPS
CONSULT-II Inspection Procedure
EL-109
CONSULT-II Application Items
NHEL0214
“INT LAMP”
NHEL0214S01
Data Monitor
NHEL0214S0101
Monitored Item
Description
IGN ON SW
Indicates [ON/OFF] condition of ignition switch.
DOOR SW-RR
Indicates [ON/OFF] condition of ignition switch.
KEY ON SW
Indicates [ON/OFF] condition of key switch.
DOOR SW-DR
Indicates [ON/OFF] condition of front door switch LH.
DOOR SW-AS
Indicates [ON/OFF] condition of front door switch RH.
LOCK SW DR/AS
Indicates [ON/OFF] condition of front door lock switch.
UNLK SW DR/AS
Indicates [ON/OFF] condition of front door lock switch.
KEY CYL LK-SW
Indicates [ON/OFF] condition of front door key cylinder switch.
KEY CYL UN-SW
Indicates [ON/OFF] condition of front door key cylinder switch.
LK BUTTON/SIG
Indicates [ON/OFF] condition of unlock signal from remote controller.
UN BUTTON/SIG
Indicates [ON/OFF] condition of unlock signal from remote controller.
Active Test
NHEL0214S0102
Test Item
Description
INT LAMP
This test enables to check interior lamp operation.
When “ON” on CONSULT-II screen is touched:
I
Interior lamp turns on when the switch is at DOOR.
(Smart entrance control unit supplies power and ground to interior lamp.)
IGN ILLUM
This test enables to check ignition key hole illumination operation. The illumination turns on when
“ON” on CONSULT-II screen is touched.
STEP LAMP
This test enables to check step lamp operation.
The illumination turns on when “ON” on CONSULT-II screen is touched.
Work Support
NHEL0214S0103
Work Item
Description
ROOM LAMP TIMER SET
Interior lamp timer mode can be changed by mode setting. Selects ON-OFF of the room lamp
illumination at the time the driver door is unlocked.
“BATTERY SAVER”
NHEL0214S02
Data Monitor
NHEL0214S0201
Monitored Item
Description
IGN ON SW
Indicates [ON/OFF] condition of ignition switch.
DOOR SW-RR
Indicates [ON/OFF] condition of ignition switch.
KEY ON SW
Indicates [ON/OFF] condition of key switch.
DOOR SW-DR
Indicates [ON/OFF] condition of front door switch LH.
DOOR SW-AS
Indicates [ON/OFF] condition of front door switch RH.
LOCK SW DR/AS
Indicates [ON/OFF] condition of front door lock switch.
UNLK SW DR/AS
Indicates [ON/OFF] condition of front door lock switch.
KEY CYL LK-SW
Indicates [ON/OFF] condition of front door key cylinder switch.
INTERIOR, STEP, SPOT, VANITY MIRROR AND TRUNK ROOM LAMPS
CONSULT-II Application Items
EL-110
Monitored Item
Description
KEY CYL UN-SW
Indicates [ON/OFF] condition of front door key cylinder switch.
LK BUTTON/SIG
Indicates [ON/OFF] condition of unlock signal from remote controller.
UN BUTTON/SIG
Indicates [ON/OFF] condition of unlock signal from remote controller.
Active Test
NHEL0214S0202
Test Item
Description
BATTERY SAVER
This test enables to check interior lamp, front step lamps, spot lamp, vanity mirror illuminations
and trunk room lamp operations.
When touch “ON” on CONSULT-II screen.
I
Interior lamp turns on when the switch is in ON.
(Smart entrance control unit supplies power to interior lamp.)
I
Front step lamps turn on when any doors are open.
(Smart entrance control unit supplies power to front step lamps.)
I
Spot lamp, vanity mirror illuminations, trunk room lamp turn on when the switch is in ON.
(Smart entrance control unit supplies power to Spot lamp, vanity mirror illuminations, trunk
room lamp.)
Work Support
NHEL0214S0203
Work Item
Description
ROOM LAMP BAT SAV SET
Interior lamp battery saver control period can be changed by mode setting. Selects interior lamp
battery saver control period between two modes.
I
MODE 1 (30 minutes)/MODE 2 (60 minutes)
GI
MA
EM
LC
EC
FE
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
INTERIOR, STEP, SPOT, VANITY MIRROR AND TRUNK ROOM LAMPS
CONSULT-II Application Items (Cont’d)
EL-111
Trouble Diagnoses for Interior Lamp Timer
=NHEL0215
DIAGNOSTIC PROCEDURE 1
NHEL0215S01
SYMPTOM: Interior lamp timer does not operate.
1
CHECK IGNITION ON SIGNAL
With CONSULT-II
Check ignition switch ON signal (“IGN ON SW”) in “DATA MONITOR” mode with CONSULT-II.
SEL318W
Without CONSULT-II
Check voltage between smart entrance control unit harness connector M144 terminal 27 (G) and ground.
SEL003Y
OK or NG
OK
©
GO TO 2.
NG
©
Check the following.
I
10A fuse [No. 10, located in fuse block (J/B)]
I
Harness for open or short between smart entrance control unit and fuse
INTERIOR, STEP, SPOT, VANITY MIRROR AND TRUNK ROOM LAMPS
Trouble Diagnoses for Interior Lamp Timer
EL-112