Infiniti M35/M45 Y50. Manual — part 726
ASCD BRAKE SWITCH
EC-1377
[VK45DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
ASCD BRAKE SWITCH
PFP:25320
Component Description
NBS005QJ
When the brake pedal is depressed, ASCD brake switch (2) is
turned OFF and stop lamp switch (1) is turned ON. ECM detects the
state of the brake pedal by this input of two kinds (ON/OFF signal).
Refer to
EC-738, "AUTOMATIC SPEED CONTROL DEVICE
for the ASCD function.
CONSULT-II Reference Value in Data Monitor Mode
NBS005QK
Specification data are reference values.
PBIB2705E
MONITOR ITEM
CONDITION
SPECIFICATION
BRAKE SW1
(ASCD brake switch)
●
Ignition switch: ON
Brake pedal: Fully released
ON
Brake pedal: Slightly depressed
OFF
BRAKE SW2
(Stop lamp switch)
●
Ignition switch: ON
Brake pedal: Fully released
OFF
Brake pedal: Slightly depressed
ON
EC-1378
[VK45DE]
ASCD BRAKE SWITCH
Wiring Diagram
NBS005QL
TBWT1068E
ASCD BRAKE SWITCH
EC-1379
[VK45DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic Procedure
NBS005QM
1.
CHECK OVERALL FUNCTION-I
With CONSULT-II
1.
Turn ignition switch ON.
2.
Select “BRAKE SW1” in “DATA MONITOR” mode with CONSULT-II.
3.
Check “BRAKE SW1” indication under the following conditions.
Without CONSULT-II
1.
Turn ignition switch ON.
2.
Check voltage between ECM terminal 108 and ground under the
following conditions.
OK or NG
OK
>> GO TO 2.
NG
>> GO TO 3.
TER-
MINAL
NO.
WIRE
COLOR
ITEM
CONDITION
DATA (DC Voltage)
101
V/R
Stop lamp switch
[Ignition switch: OFF]
●
Brake pedal: Fully released
Approximately 0V
[Ignition switch: OFF]
●
Brake pedal: Slightly depressed
BATTERY VOLTAGE
(11 - 14V)
108
BR
ASCD brake switch
[Ignition switch: ON]
●
Brake pedal: Slightly depressed
Approximately 0V
[Ignition switch: ON]
●
Brake pedal: Fully released
BATTERY VOLTAGE
(11 - 14V)
CONDITION
INDICATION
Brake pedal: Slightly depressed
OFF
Brake pedal: Fully released
ON
SEC011D
CONDITION
VOLTAGE
Brake pedal: Slightly depressed
Approximately 0V
Brake pedal: Fully released
Battery voltage
MBIB0061E
EC-1380
[VK45DE]
ASCD BRAKE SWITCH
2.
CHECK OVERALL FUNCTION-II
With CONSULT-II
Check “BRAKE SW2” indication in “DATA MONITOR” mode.
Without CONSULT-II
Check voltage between ECM terminal 101 and ground under the following conditions.
OK or NG
OK
>> INSPECTION END
NG
>> GO TO 8.
CONDITION
INDICATION
Brake pedal: Fully released
OFF
Brake pedal: Slightly depressed
ON
SEC013D
CONDITION
VOLTAGE
Brake pedal: Fully released
Approximately 0V
Brake pedal: Slightly depressed
Battery voltage
PBIB1537E