QUARTER WINDOW GLASS AND REGULATOR ASSEMBLY
TSB Revision
BODY
42-39
6. Press the up-stop against the quarter window glass stop,
and then tighten the up-stop bolt.
7. Lock the adjusting bolt with a nut.
CAUTION
Ensure that the weatherstrip is not wrinkled or out of
position.
8. Install the topstack rear rail weatherstrip. (Refer to
9. Install the quarter lower trim. (Refer to GROUP 52A
10.Check the quarter window glass alignment according to the
following procedure.
(1) The upper end of the front door glass and the quarter
window glass should be positioned so that standard
value (a) is met.
Standard value (a): 1.0
±
1.0 mm (0.04
±
0.04 inches)
(2) The front door glass and the quarter window glass should
be positioned to meet standard value (c) so that gap in
their upper end lines is smooth.
Standard value (c): 3.0
±
1.0 mm (0.12
±
0.04 inches)
(3) The end line of the front door glass and the front line of
the quarter window glass should be parallel in the interval
of standard value (b).
Standard value (b): 8.7 mm (0.34 inches)
AC003343AB
QUARTER
WINDOW
GLASS
UP-STOP BOLT
AC003344
QUARTER WINDOW GLASS
FRONT DOOR
GLASS
a
b
c
QUARTER WINDOW
GLASS
AB
QUARTER WINDOW GLASS AND REGULATOR ASSEMBLY
TSB Revision
BODY
42-40
QUARTER WINDOW GLASS AND REGULATOR ASSEMBLY
REMOVAL AND INSTALLATION
M1422006000028
REMOVAL SERVICE POINTS
<<A>> QUARTER WINDOW GLASS REMOVAL
1. Completely raise the quarter window.
2. Remove the quarter window
<<B>> QUARTER WINDOW REGULATOR ASSEMBLY
REMOVAL
Disconnect regulator motor connector, remove the quarter
window regulator assembly.
Post-installation Operation
•
Quarter Window Glass Adjustment (Refer to
.)
AC003345AB
1
4
3
8 ± 1.5 N·m
71 ± 13 in-lb
2
4
POWER WINDOW MAIN SWITCH
SWITCH REMOVAL STEPS
1. POWER WINDOW MAIN SWITCH
(REFER TO.)
QUARTER WINDOW GLASS
REMOVAL STEPS
•
REAR SPEAKER GARNISH (REFER
TO GROUP 52A
•
QUARTER BELT MOULDING
(REFER TO GROUP 51
.)
<<A>>
2. QUARTER WINDOW GLASS
QUARTER WINDOW REGULATOR
ASSEMBLY REMOVAL STEPS
<<A>>
2. QUARTER WINDOW GLASS
•
QUARTER TRIM (REFER TO
GROUP 52A
.)
•
REAR SPEAKER (REFER TO
GROUP 54A
3. QUARTER WINDOW INNER
BELTLINE MOULDING
<<B>>
4. QUARTER WINDOW REGULATOR
ASSEMBLY
DOOR
TSB Revision
BODY
42-41
INSPECTION
M1429003900012
QUARTER WINDOW REGULATOR MOTOR CHECK
Check that motor runs smoothly when the battery is connected
directly to the motor terminals.
Furthermore, check that the motor operates in reverse when
the terminal connections are switched.
D O O R
GENERAL DESCRIPTION
M1423000100075
OPERATION
CENTRAL DOOR LOCKING SYSTEM
The central door locking system operates the door
lock actuator to lock or unlock the doors using the
operation of the door lock switch or key built into the
driver's side inside door lock knob and power window
(main or sub) switch.The system has the following
operations and features:
•
All doors can be locked or unlocked using the
door (LH or RH) key cylinder key operation.
•
All doors can be locked using the driver's inside
door lock knob.
•
All doors can be locked using the door lock
switch built into the power window (main or sub)
switch.
•
You cannot lock an open door if the key is in the
ignition switch. The key reminder function
automatically unlocks all doors when the door is
locked.
Power windows
Power windows are used in all vehicles. When the
power window (main or sub) switch is operated, the
door windows will open or close. This system has the
following operations and features:
•
When the power window main switch lock/unlock
switch is locked, the door windows can only be
opened or closed by the power window main
switch on the driver's door.
•
When all doors are closed and the ignition is
turned off, the power windows can be operated
for 30 seconds from the time the ignition is turned
off.
•
The power window main switch contains a one-
touch down switch that will automatically fully
open driver's side door window only.
CENTRAL DOOR LOCKING SYSTEM DIAGNOSIS
M1427000700057
The central door locking system is controlled by the
smart wiring system (SWS). For troubleshooting,
refer to GROUP 54B, Diagnosis
.
AC003346
QUARTER WINDOW
REGULATOR ASSEMBLY
AB
DOOR
TSB Revision
BODY
42-42
POWER WINDOW DIAGNOSIS
INTRODUCTION TO POWER WINDOWS DIAGNOSIS
M1429002600052
The power window relay is controlled by the smart
wiring system (SWS). For troubleshooting, refer to
GROUP 54B, Diagnosis
. When the power
window switch (main or sub) is operated, the power
window motor operates and opens or closes the door
window.
A timer function has been provided to allow the door
windows to be opened or closed in 30 seconds after
the ignition switch is turned from "ON" to "LOCK"
(OFF) position when a front door <LH> and <RH> is
closed (door switch is OFF). When the lock switch is
changed from unlock to lock, the door windows can
only be opened or closed by the power window main
switch on the driver's side.
If the following types of symptom occur, there may be
a fault.
•
None of the door windows open or close.
•
There are door windows that do not open or close
using the power window (main or sub) switch.
•
The windows cannot be opened or closed using
the power window (main or sub) switch within 30
seconds after the ignition switch is turned from
"ON" to "LOCK" (OFF) position.
POWER WINDOWS DIAGNOSTIC TROUBLESHOOTING STRATEGY
M1429002700059
Use these steps to plan your diagnostic strategy. If
you follow them carefully, you will be sure that you
have exhausted most of the possible ways to find a
power windows fault.
1. Gather information from customer.
2. Verify that the condition described by the
customer exists.
3. Find the malfunction by following the Symptom
Chart.
4. Verify malfunction is eliminated.
SYMPTOM CHART
M1429002800067
SYMPTOMS
INSPECTION
PROCEDURE
REFERENCE PAGE
None of the door windows open or close.
-
Only the front door window <LH> does not open and close.
1
Only the front door window <RH> does not open and close.
2
There are door windows that do not open or close using the
power window sub switch (on passenger's door). (However,
they open or close when the power window main switch is
used.)
3
None of the door windows are opened or closed by the
power window main switch (on driver's door). (However, they
are opened or closed by the power window sub switch.)
4
The door windows cannot be opened or closed by the power
window (main or sub) switch within 30 seconds after the
ignition switch is turned from "ON" to "LOCK" position.
(However, this is before the front doors LH and RH are
opened.)
-