SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR
54B-88
Step 2. Pulse check
Check the input signals below which are related to
the encrypted code of the keyless entry transmitter.
OK: The M.U.T.-III sounds or the voltmeter
needle fluctuates.
Q: Are the check result normal?
All the signals are received normally. :
Go to Step
3.
The key reminder switch signal is not received. :
Refer to Inspection Procedure N-7 "The key
reminder switch signal is not received
."
The hazard warning lamp switch signal is not
received. :
Refer to Inspection Procedure N-9
"The hazard warning lamp switch signal is
not received
The keyless entry transmitter switch signal is not
received. :
Refer to Inspection Procedure N-12
"Each switch signal of the keyless entry
transmitter is not received
Step3. Retest the system.
Check that the encrypted code can be registered.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00
− How to
use Troubleshooting/inspection Service
Points
− How to Cope with Intermittent
).
NO :
Replace the ETACS-ECU.
System switch
Check condition
Key reminder switch
When the inserted
ignition key is pulled out
Hazard warning lamp
switch
When the switch is
turned from off to on
Keyless entry transmitter
switch
When the switch is
turned from off to on
Main
Index
Group
TOC
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR
54B-89
INSPECTION PROCEDURE E-4: Multimode keyless entry system function does not work at all.
CAUTION
Whenever the ECU is replaced, ensure that the
input and output signal circuits are normal.
COMMENTS ON TROUBLE SYMPTOM
If the power windows and the electric-folding door
mirrors work normally, the ETACS-ECU may be
defective.
POSSIBLE CAUSES
• Malfunction of the ETACS-ECU
• Malfunction of the keyless entry transmitter
DIAGNOSIS PROCEDURE
Step 1. Check the electric retractable remote
controlled door mirror.
Check that the electric retractable remote controlled
door mirror works normally.
Q: Is the check result normal?
YES :
Go to Step 2.
NO :
Refer to inspection procedure H-1 "Electric
retractable remote controlled door mirror
does not work at all
Step 2. Check the operation of the keyless entry
system.
Check that the keyless entry system works normally.
Q: Is the check result normal?
YES :
Go to Step 3.
NO :
Refer to inspection procedure E-1 "Keyless
entry system does not work
."
Step 3. Check the power supply circuit.
When the ignition switch is turned to the LOCK
(OFF) position, check if the hazard warning lamps
illuminate.
Q: Is the check result normal?
YES :
Go to Step 4.
NO :
Refer to Inspection Procedure A-2 "When
the ignition switch is at the LOCK (OFF)
position, the functions do not work normally.
Check the battery power supply circuit to
the ETACS-ECU
."
Step 4. Retest the system.
Check that the multi-mode keyless entry system
works normally.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00
− How to
use Troubleshooting/inspection Service
Points
− How to Cope with Intermittent
).
NO :
Replace the ETACS-ECU.
Main
Index
Group
TOC
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR
54B-90
INSPECTION PROCEDURE E-5: The Timer Lock Function does not Work after the Doors have been
Unlocked by the Keyless Entry System.
CAUTION
Whenever the ECU is replaced, ensure that the
input and output signal circuits are normal.
COMMENT ON TROUBLE SYMPTOM
If the keyless entry timer lock does not work nor-
mally, the input signal circuit(s) to the keyless entry
transmitter or the ETACS-ECU may be defective.
POSSIBLE CAUSES
• Malfunction of the keyless entry transmitter
• Malfunction of the ETACS-ECU
• Damaged harness wires and connectors
DIAGNOSIS PROCEDURE
Step 1. Check the operation of the keyless entry
system.
Check that the keyless entry system works normally.
Q: Is the check result normal?
YES :
Go to Step 2.
NO :
Refer to inspection procedure E-1 "Keyless
entry system does not work
."
Step 2. Customize function by using the SWS
monitor.
"KEYLESS LOCK T" is set to one of the followings by
using SWS monitor customisation function. Check
that the timer lock is activated according to the set-
ting.
• 30s
• 60s
• 120s
• 180s
CAUTION
The SWS monitor must be used in order to con-
firm and change that setting. Use the SWS moni-
tor to confirm and/or change the customised
function.
Q: Is the check result normal?
YES :
Go to Step 3.
NO :
Enable the keyless entry timer lock function
by using the SWS monitor customise
function (Refer to GROUP 54C
− Customize
function
Step 3. Retest the system.
Check that the timer lock works normally.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00
− How to
use Troubleshooting/inspection Service
Points
− How to Cope with Intermittent
).
NO :
Replace the ETACS-ECU.
Main
Index
Group
TOC
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR
54B-91
WINDSHIELD WIPER AND WASHER
INSPECTION PROCEDURE F-1: The windshield wipers does not work at all.
CAUTION
Whenever the ECU is replaced, ensure that the
input and output signal circuits are normal.
IGNITION
SWITCH (ACC)
ETACS-ECU
J/B SIDE
CIRCUIT
BREAKER
WIPER SPEED
SWITCHING
RELAY
WINDSHIELD
WIPER MOTOR
Wire colour code
B : Black LG : Light green G : Green L : Blue W : White Y : Yellow SB : Sky blue
BR : Brown O : Orange GR : Gray R : Red P : Pink V : Violet
Windshield Wiper Power Supply Circuit
Main
Index
Group
TOC
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.