Great Wall Hover. Manual — part 93
![](/vehicles/ringoyo/jeeba/vevebe/zcove.png)
Safety airbag-9
Project 3 functional working (neither possible explosion failure or historical failure).
Table 4.9 indicator lamp’s activities after ignition
2.Failure indication
The alarm lamp will indicate it in case any failure arises. If the external failure is a historical one, the indication will be called off. If
the number of history-accumulated failures is or more than 5, the alarm lamp will keep illuminating albeit no failure emerges. The
case of low power will be excluded.
A displayed or historical failure can but only be reconfigured by the service personnel. An internal failure or impact record can not
be reconfigured, in these cases, SRS-ECU must be replaced.
3.Micro controller-independent alarm lamp illumination
The micro-controller in clear failure status can not work therefore can not control the alarm lamp. In this case, the alarm lamp
will be directly lighted via suitable circuit despite of the micro-controller. As following,
The battery for SRS-ECU fails, the alarm lamp will be continuously lighted through the lamp drive function.
b. No internal working voltage, the alarm lamp keeps illuminating
c. Reconfiguration caused by watchdog’s trigging failure, the alarm lamp flashes.
d. No work of micro-controller, the alarm lamp keeps illuminating
e. Incomplete plugging-in of SRS-ECU connector, the alarm lamp keeps illuminating via shoring bar Next explain the diagnostic
procedure by taking some examples
If the alarm lamp is found keeping illuminating, please test it according to the following procedure even it extinguishes finally.
First test the failure region with the scanner followed by the test in the failure region with the corresponding approaches and
steps.
a If an internal failure or the explosion of safety airbag is scanned, replace the SRS-ECU
b.Troubleshooting
Project 2. The number of history- accumulated failures is or more than one and less than 5. (The case of low power is excluded)
![](/vehicles/ringoyo/jeeba/vevebe/sar.png)
Safety airbag-10
1. Extinguishments of safety airbag system alarm lamp
Troubleshooting
Extinguishments or normal-light of alarm lamp
NO. Troubleshooting
item
Description
1
The warning lamp of safety airbag
system is not displayed.
Safety airbag system warns circuit failure
2
The warning lamp of safety airbag
system is light normally.
Safety airbag system warns circuit failure or external
failure.
1
Extinguishments of safety airbag system alarm lamp
Test status
Safety airbag system warns circuit failure.
Possible causes
No voltage (fuse shutoff)
Combined instrument failure
Failure of wiring harness between instrument cluster and ECU unit
Diagnostic procedure
When first carry out failure test, joggle the wiring harness and plug to test whether there is periodical bad contact in the circuit, if
it so, please confirm whether the plug, terminal and wiring harness well connected and in good condition. If it is not any of previous
cases, operate according to the following steps.
Procedure
Test
Operation
Yes
Place the ignition switch in LOCK
position followed by next step
1
Test other wiring harness and instrument cluster
indicator lamp
·
place the ignition switch in ON position
·
light other alarm and indicator lamps
No
Test the instrument cluster power-supply
system and grounding system (fuse), then
go to step 5.
Yes Next
step
2
Bulb test
Warning:
Incorrect handling with the safety airbag system
units will cause the safety airbag’s improper
release and pretension of safety belt, which will
lead to serene accidents. Please read safety airbag
service warning before handling the safety airbag
units.
·
Place the ignition switch in LOCK position。
·
shut off accumulator negative line and keep the
status for at least 60 seconds.
·
Remove the combined instrument.
Test the connection between the two
corresponding stitches of safety airbag alarm lamp
No
Replace the bulb of alarm lamp.
![](/vehicles/ringoyo/jeeba/vevebe/god.png)
Safety airbag-11
2. Normal-light of safety airbag system indicator lamp
2
Normal-light of safety airbag system alarm lamp
Test status
Normal-light of safety airbag system alarm lamp
Possible causes
Insufficient battery voltage
ECU internal failure
Combined instrument safety airbag alarm lamp failure
ECU plug misconnects
Combined instrument plug bad-contact
ECU power-supply fuse shutoff or bad contact
Misconnection of ECU plug terminal
Bad contact between ECU plug terminal and grounding wiring
harness.
Driver’s or passengers’ side safety airbag circuit failure.
Procedure
Test
Operation
Yes Next
procedure.
3
Test the wiring harness connection between ECU
unit and instrument cluster.
·
Place the ignition switch in LOCK position。
·
shut off accumulator negative line
·
shut off the instrument cluster plug
·
test the connection between alarm lamp circuit
and its relative circuits
No
Replace the wiring harness and get into
step 5
![](/vehicles/ringoyo/jeeba/vevebe/quellutrldel.png)
Safety airbag-12
Begin the test with diagnostic communication with special diagnostic device (X-431 diagnostic tester) and ECU
to find out the failure causes, do the next test providing communication is not successful.
Procedure
Test
O peration
Yes Next
procedure
1
Test the battery
Test the battery voltage
Is the voltage higher 9V?
No
Insufficient battery supply.
Test the charging/discharging
system, then go to step 5.
Yes Next
step
2
Test the wiring harness connection between ECU and
combined instrument.
Place the ignition switch in LOC K position。
Shut off the battery negative.
Open the central channel guard plate.
Shut off the instrument combined connector clip
Connect the negative of battery
Place the ignition switch in ON position.
Check whether the instrument connector clip terminal
voltage is 12V(power supply and instrument line)
No
Check the circuit and continue the
operation according to step 5.
Yes Next
step
3
Place the ignition switch in LOC K position。
Check the connection of corresponding terminals between
instrument connector clip and diagnostic interface
(diagnose the two ends of K-line)
No
Repair or replace the wiring
harness and continue according to
step 5
Yes Next
step
3
Make sure the shutoff of accumulator negative line and
keep the status for at least 1 minute.
Shut off ECU connector clip
Shut off the instrument cluster plug.
Connect the ECU plug terminal 5,7,9 and instrument
cluster plug?
No
Replace the wiring harness and
step 5
Yes Replace
ECU
4
Remove EC U to check the condition of terminal and
whether the shorting bar is broken.
No
Reconnect EC U connector clip
and next step.
Yes
Troubleshooting followed by the
explanations to customers upon
the repairing procedure.
5
Make sure that the failure will never reoccur after
repairing.
Place the ignition switch in LOC K position。
Shut off accumulator negative line and keep the status for
at least 1 minute.
Connect all ECU plugs
Connect the driver’s side safety airbag combined
instrument plug
Connect the passengers’ side safety airbag combined
instrument plug
Connect the driver and passengers’ side pretension safety
belts plugs.
(Vehicles with pretension safety-belts)
Connect clock spring plug
Connect the accumulator negative line
Place the ignition switch in ON position
Does the safety airbag alarm lamp work functionally?
No
Retest the failure symptoms;
repeat from step 1 if the failure
reoccurs.