Defender. Manual — part 207
4. Remove the blower motor.
Remove the 3 screws.
Installation
1. To install, reverse the removal procedure.
Apply a bead of sealant to the mating faces of the
blower motor and blower motor housing.
sealant
2. Tighten to 10 Nm (7 lb.ft).
Heating and Ventilation - Heater Control Valve
Removal and Installation
Removal
1. Remove the bonnet switch.
Disconnect the bonnet switch electrical connector.
2. NOTE: Note the fitted position of the cable prior to
removal.
Disconnect the heater control valve control cable.
Release the clip.
3. Disconnect the heater core feed hose.
Using a suitable pipe clamp, clamp the hose.
Release the clip.
4. Disconnect the heater control valve feed and return hoses.
Using a suitable pipe clamp, clamp the hoses.
Release the 2 clips.
5. Disconnect the heater core return hose.
Release the clip.
6. Release the heater control valve.
Remove the nut.
7. Remove the heater control valve.
Remove the bolt.
Installation
1. To install, reverse the removal procedure.
Tighten to 22 Nm (16 lb.ft).
2. Tighten to 6 Nm (4 lb.ft).
2. Tighten to 6 Nm (4 lb.ft).