Toyota Sequoia (2005). Manual — part 949
N20013
R–Shape
Rotor
Snap Ring
Compressor
AC1743
AC1744
AC0950
SST
N20012
R–Shape
Snap Ring
Compressor
Stator
AC–58
–
AIR CONDITIONING
COMPRESSOR AND MAGNETIC CLUTCH
3785
NOTICE:
The snap ring should be installed so that its beveled side
faces up.
(b)
Using a plastic hammer, remove the rotor from the shaft.
NOTICE:
Be careful not to damage the pulley when tapping on the ro-
tor.
3.
REMOVE STATOR
(a)
Disconnect the stator lead wire from the compressor
housing.
(b)
Using SST, remove the snap ring.
SST
95994–10020
NOTICE:
The snap ring should be installed so that its beveled side
faces up.
AC0951
Stator
–
AIR CONDITIONING
COMPRESSOR AND MAGNETIC CLUTCH
AC–59
3786
(c)
Remove the stator.
N04963
Dial Indicator
AC1L3–04
AC–60
–
AIR CONDITIONING
COMPRESSOR AND MAGNETIC CLUTCH
3787
REASSEMBLY
Reassembly is in the reverse order of disassembly (See
page
AFTER REASSEMBLY, CHECK MAGNETIC CLUTCH
CLEARANCE
(a)
Set the dial indicator to the pressure plate of the magnetic
clutch.
(b)
Connect the magnetic clutch lead wire to the positive (+)
terminal of the battery.
(c)
Check the clearance between the pressure plate and ro-
tor when connecting the negative (–) terminal to the bat-
tery.
Standard clearance:
0.35
to
0.50 mm (0.014
to 0.024 in.)
If the clearance is not within the standard range, adjust the
clearance using shims to obtain the standard clearance.
Standard thickness:
0.1 mm (0.004 in.)
0.3 mm (0.012 in.)
0.5 mm (0.020in.)
AC3HF–02
–
AIR CONDITIONING
COMPRESSOR AND MAGNETIC CLUTCH
AC–61
3788
INSTALLATION
1.
INSTALL COMPRESSOR
(a)
Install the compressor with the cooler bracket with the 3 bolts and nut.
Torque:
Bolt: 47 N·m (480 kgf·cm, 35 in.·lbf)
Nut: 25 N·m (255 kgf·cm, 18 in.·lbf)
(b)
Connect the connector.
2.
CONNECT DISCHARGE AND SUCTION HOSES
Connect both hoses with the 2 nuts.
Torque: 10 N·m (100 kgf·cm, 7 in.·lbf)
NOTICE:
Hoses should be connected immediately after the caps have been removed.
HINT:
Lubricate 2 new O–rings with compressor oil and install them to the hoses.
3.
INSTALL AND CHECK DRIVE BELT (See page
4.
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
5.
EVACUATE AIR FROM REFRIGERATION SYSTEM
6.
CHARGE SYSTEM WITH REFRIGERANT
Specified amount:
Single A/C: 750
±
50g (26.45
± 1.76 oz.)
Dual A/C: 1050 ±
50g (37.03
± 1.76 oz.)
7.
INSPECT FOR LEAKAGE OF REFRIGERANT
Using a gas leak detector, check for leakage of refrigerant.
If there is leakage, check the tightening torque at the joints.
8.
PERFORM INITIALIZATION (See page
Some systems need initialization when disconnecting the cable from the negative battery terminal.