Kia Carnival (2007 year). Manual — part 581
![](/vehicles/jado/eand/bondeakie/eep.png)
INSTALLATION
Install the canister according to the reverse order of "REMOVAL" procedure.
INSPECTION
1. Look for loose connections, sharp bends or damage to the fuel vapor lines.
2. Look for distortion, cracks or fuel damage.
3. After removing the canister, inspect for cracks, damage or saturated canister.
Purge Control Solenoid
Valve
(PCSV)
![](/vehicles/jado/eand/bondeakie/ikserave.png)
2007 > 3.8L V6 GASOLINE >
INSPECTION
When disconnecting the vacuum hose, make an identification mark on it so that it can be reconnected to its
original position.
1. Disconnect the vacuum hose from the solenoid valve.
2. Detach the harness connector.
3. Connect a vacuum pump to the nipple which is connected to intake manifold.
4. Apply vacuum and check when voltage is applied to the PCSV and when the voltage is discontinued.
Battery voltage
Normal condition
When applied
Vacuum is released
When discontinued
Vacuum is maintained
5. Measure the resistance between the terminals of the solenoid valve.
PCSV coil resistance(Ω) :
19.0 ~ 22.0Ω at 20°C (68°F)
DESCRIPTION
Purge Control Solenoid Valve (PCSV) is installed on the surge tank and controls the passage between the canister
and the intake manifold. It is a solenoid valve and is open when the PCM grounds the valve control line. When the
passage is open (PCSV ON), fuel vapors stored in the canister is transferred to the intake manifold.
SPECIFICATION
Item
Specification
Coil Resistance (Ω)
19.0 ~ 22.0Ω at 20°C (68°F)
SCHEMATIC DIAGRAM