Almera Tino V10 (2003 year). Manual — part 162
![](/vehicles/gon/lennod/ficar/kenke.png)
YEL951D
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
INTERIOR ROOM LAMP
Wiring Diagram — ROOM/L — (Cont’d)
EL-81
![](/vehicles/gon/lennod/ficar/gofa.png)
YEL952D
INTERIOR ROOM LAMP
Wiring Diagram — ROOM/L — (Cont’d)
EL-82
![](/vehicles/gon/lennod/ficar/urn.png)
Terminal and Reference Valve for Smart
Entrance Control Unit
NLEL0680
Terminal
No.
Wire
color
Connections
Operated condition
Voltage (Approximate values)
5
B/R
Key switch
Ignition key Removed
,
Inserted
0V
,
12V
13
GY
Door lock/unlock switches
Neutral
,
Locks
12V
,
0V
14
L
Door lock/unlock switches
Neutral
,
Unlocks
12V
,
0V
28
R/Y
Interior room lamp
When interior lamp is operated using
remote controller (Lamp switch in
“DOOR” position)
12V
,
0V
29
Y/G
Ignition key switch
Ignition key is in “ON” position
12V
43
R/W
Front door switch
Front door (Driver side):
Open
,
Closed
12V
,
0V
44
L/OR
Front door switch
(Passenger side)
Front door (Passenger side):
Open
,
Closed
0V
,
12V
53
B
Ground
—
0V
56
R/B
Power source
—
12V
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
INTERIOR ROOM LAMP
Terminal and Reference Valve for Smart Entrance Control Unit
EL-83
![](/vehicles/gon/lennod/ficar/myousery.png)
MBIB0906E
CONSULT-II Inspection Procedure
=NLEL0681
“ROOM LAMP”
1.
Turn ignition switch “OFF”.
2.
Connect “CONSULT-II” to the data link connector.
MBIB0233E
3.
Turn ignition switch “ON”.
4.
Touch “START (NISSAN BASED VHCL)”.
YEL322E
5.
Touch “SMART ENTRANCE”.
YEL324E
6.
Touch “ROOM LAMP”.
SEL788W
7.
Select diagnosis mode.
“DATA MONITOR” are available for “ROOM LAMP”.
INTERIOR ROOM LAMP
CONSULT-II Inspection Procedure
EL-84
![](/vehicles/gon/lennod/ficar/quput.png)
CONSULT-II Application Items
NLEL0682
ROOM LAMP
Data Monitor Mode
Item (CONSULT-II screen terms)
Diagnosed system
IGNITION SW
Indicates [ON/OFF] condition of ignition switch.
KEY IN DETECT
Indicates [ON/OFF] condition of electronic key switch.
DOOR SW DR RR
Indicates [ON/OFF] condition of rear door switch (driver side).
DOOR SW AS RR
Indicates [ON/OFF] condition of rear door switch (passenger side).
AS DOOR SW
Indicates [ON/OFF] condition of front door switch (passenger side).
DR DOOR SW
Indicates [ON/OFF] condition of front door switch (driver side).
CDL LOCK SW
Indicates [ON/OFF] condition of door lock/unlock switch (lock signal).
CDL UNLOCK SW
Indicates [ON/OFF] condition of door lock/unlock switch (unlock signal).
RKE LOCK
Indicates [ON/OFF] condition of lock signal from remote controller.
RKE UNLOCK
Indicates [ON/OFF] condition of unlock signal from remote controller.
RKE SEL UNLOCK
Indicates [ON/OFF] condition of select unlock signal from remote controller.
KEY CYL LK
Indicates [ON/OFF] condition of lock signal from door key cylinder.
KEY CYL UNLK
Indicates [ON/OFF] condition of unlock signal from door key cylinder.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
INTERIOR ROOM LAMP
CONSULT-II Application Items
EL-85
![](/vehicles/gon/lennod/ficar/reeding.png)
Trouble Diagnoses
=NLEL0533
DIAGNOSTIC PROCEDURE 1
NLEL0533S04
Symptom: Interior room lamp timer does not operate
NLEL0533S0401
1
CHECK IGNITION ON SIGNAL
WITH CONSULT-II
Check ignition switch ON signal (“IGNITION SW”) in “DATA MONITOR” mode with CONSULT-II.
MKIB0196E
When ignition switch is ON: IGNITION SW ON
When ignition switch is OFF: IGNITION SW OFF
WITHOUT CONSULT-II
1. Disconnect smart entrance control unit.
2. Check voltage between smart entrance control unit harness connector M100 terminal 29 (Y/G) and ground.
MKIB0072E
MTBL1635
OK or NG
OK
©
GO TO 2.
NG
©
Check the following.
I
10A fuse [No. 10, located in fuse block (J/B)]
I
Harness for open or short between smart entrance control unit and fuse
INTERIOR ROOM LAMP
Trouble Diagnoses
EL-86
![](/vehicles/gon/lennod/ficar/pssth.png)
2
CHECK DOOR SWITCH INPUT SIGNAL
WITH CONSULT-II
Check driver door switch signal (“DR DOOR SW”) in “DATA MONITOR” mode with CONSULT-II.
MKIB0197E
When driver’s door switch is open: DR DOOR SW ON
When driver’s door switch is closed: DR DOOR SW OFF
WITHOUT CONSULT-II
1. Connect smart entrance control unit connector.
2. Check voltage between smart entrance control unit harness connector M100 terminal 43 (R/W) and ground.
MKIB0073E
MTBL1423
OK or NG
OK
©
GO TO 4.
NG
©
GO TO 3.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
INTERIOR ROOM LAMP
Trouble Diagnoses (Cont’d)
EL-87
![](/vehicles/gon/lennod/ficar/thebowig.png)
3
CHECK DRIVER SIDE DOOR SWITCH
1. Disconnect door switch driver side connector.
2. Check continuity between door switch driver side harness connector B28 terminals 2 and 3.
YEL348E
OK or NG
OK
©
Check harness for open or short between smart entrance control unit and door switch
driver side.
NG
©
Replace door switch driver side.
INTERIOR ROOM LAMP
Trouble Diagnoses (Cont’d)
EL-88
![](/vehicles/gon/lennod/ficar/cod.png)
4
CHECK DOOR LOCK/UNLOCK SWITCH
WITH CONSULT-II
Check door lock/unlock switch signal (“CDL LOCK SW” or “CDL UNLOCK SW”) in “DATA MONITOR” mode with CON-
SULT-II.
MKIB0198E
When door lock/unlock is locked:
CDL LOCK SW ON
CDL UNLOCK SW OFF
When door lock/unlock is unlocked:
CDL LOCK SW OFF
CDL UNLOCK SW ON
WITHOUT CONSULT-II
Check voltage between smart entrance control unit harness connector M99 terminals 13 (GY), 14 (L) and ground.
SIIA1567E
MTBL1636
OK or NG
OK
©
GO TO 6.
NG
©
GO TO 5.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
INTERIOR ROOM LAMP
Trouble Diagnoses (Cont’d)
EL-89
![](/vehicles/gon/lennod/ficar/ero.png)
5
CHECK DOOR LOCK/UNLOCK SWITCH
1. Disconnect power window main switch (door lock/unlock switch) harness connector.
2. Check continuity between power window main switch (door lock/unlock switch) harness connector D7 (LHD models) or
D9 (RHD models) terminals 7, 14 and 3.
YEL349E
OK or NG
OK
©
Check harness for open or short between smart entrance control unit and power window
main switch (door lock/unlock switch).
NG
©
Replace power window main switch.
6
CHECK OTHER DOORS SWITCHES INPUT SIGNAL
WITH CONSULT-II
Check other doors switch signal (“AS DOOR SW”, “RR DOOR SW” or “RR RH DOOR SW”) in “DATA MONITOR” mode
with CONSULT-II.
YEL325E
When each doors is open: AS DOOR SW ON
When each doors is closed: AS DOOR SW OFF
WITHOUT CONSULT-II
Check voltage between smart entrance control unit harness connector M100 terminal 44 (L/OR) and ground.
YEL326E
OK or NG
OK
©
GO TO 8.
NG
©
GO TO 7.
INTERIOR ROOM LAMP
Trouble Diagnoses (Cont’d)
EL-90
![](/vehicles/gon/lennod/ficar/xxthadalag.png)
7
CHECK DOOR SWITCHES
1. Disconnect door switch harness connector.
2. Check continuity between door switch terminal 1 and ground.
YEL327E
MTBL1637
OK or NG
OK
©
Check harness for open or short between smart entrance control unit and door switch.
NG
©
Replace door switch.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
INTERIOR ROOM LAMP
Trouble Diagnoses (Cont’d)
EL-91
![](/vehicles/gon/lennod/ficar/tcohen.png)
8
CHECK KEY SWITCH INPUT SIGNAL
WITH CONSULT-II
Check key switch signal (“KEY IN DETECT”) in “DATA MONITOR” mode with CONSULT-II.
MKIB0200E
When key is inserted: KEY IN DETECT ON
When key is removed: KEY IN DETECT OFF
WITHOUT CONSULT-II
Check voltage between smart entrance control unit harness connector M193 terminal 5 (L/W) and ground.
MKIB0079E
MTBL1430
OK or NG
OK
©
Replace smart entrance control unit.
NG
©
GO TO 9.
INTERIOR ROOM LAMP
Trouble Diagnoses (Cont’d)
EL-92
![](/vehicles/gon/lennod/ficar/windan.png)
9
CHECK KEY SWITCH (INSERT)
1. Disconnect key switch connector.
2. Check continuity between 1 and 2.
YEL574E
OK or NG
OK
©
Check the following.
I
10A fuse [No. 12, located in fuse block (J/B)]
I
Harness for open or short between key switch and fuse
I
Harness for open or short between smart entrance control unit and key switch
NG
©
Replace key switch.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
INTERIOR ROOM LAMP
Trouble Diagnoses (Cont’d)
EL-93
![](/vehicles/gon/lennod/ficar/nchatathet.png)
DIAGNOSTIC PROCEDURE 2
=NLEL0533S05
Symptom: Interior room lamp timer does not cancel
NLEL0533S0501
1
CHECK IGNITION ON SIGNAL
WITH CONSULT-II
Check ignition switch ON signal (“IGNITION SW”) in “DATA MONITOR” mode with CONSULT-II.
MKIB0196E
When ignition switch is ON: IGNITION SW ON
When ignition switch is OFF: IGNITION SW OFF
WITHOUT CONSULT-II
1. Disconnect smart entrance control unit connector.
2. Check voltage between smart entrance control unit harness connector M100 terminal 29 (Y/G) and ground.
MKIB0072E
MTBL1638
OK or NG
OK
©
GO TO 2.
NG
©
Check the following.
I
10A fuse [No. 10, located in fuse block (J/B)]
I
Harness for open or short between smart entrance control unit and fuse
INTERIOR ROOM LAMP
Trouble Diagnoses (Cont’d)
EL-94
![](/vehicles/gon/lennod/ficar/fia.png)
2
CHECK DOOR SWITCH INPUT SIGNAL
WITH CONSULT-II
Check driver door switch signal (“DR DOOR SW”) in “DATA MONITOR” mode with CONSULT-II.
MKIB0197E
When driver’s door switch is open: DR DOOR SW ON
When driver’s door switch is closed: DR DOOR SW OFF
WITHOUT CONSULT-II
1. Connect smart entrance control unit connector.
2. Check voltage between smart entrance control unit harness connector M100 terminal 43 (R/W) and ground.
MKIB0073E
MTBL1433
OK or NG
OK
©
GO TO 4.
NG
©
GO TO 3.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
INTERIOR ROOM LAMP
Trouble Diagnoses (Cont’d)
EL-95
![](/vehicles/gon/lennod/ficar/yost.png)
3
CHECK DOOR SWITCH DRIVER SIDE
1. Disconnect door switch driver side connector.
2. Check continuity between door switch driver side harness connector B28 terminals 2 and 3.
YEL348E
OK or NG
OK
©
Check harness for open or short between smart entrance control unit and door switch
driver side.
NG
©
Replace door switch driver side.
INTERIOR ROOM LAMP
Trouble Diagnoses (Cont’d)
EL-96