Nissan Murano. Manual — part 796
HA-20
< PRECAUTION >
LEAK DETECTION DYE
LEAK DETECTION DYE
General Precautions
INFOID:0000000009718624
CAUTION:
• The A/C system contains a fluorescent leak detection dye used for locating refrigerant leakages. An
ultraviolet (UV) lamp is required to illuminate the dye when inspecting for leakages.
• Always wear fluorescence enhancing UV safety goggles to protect the eyes and enhance the visibil-
ity of the fluorescent dye.
• The fluorescent dye leak detector is not a replacement for an electrical leak detector (SST: J-41995).
The fluorescent dye leak detector should be used in conjunction with an electrical leak detector
(SST: J-41995) to pin-point refrigerant leakages.
• Read and follow all manufacturer operating instructions and precautions prior to performing work
for safety and customer satisfaction.
• A compressor shaft seal should not necessarily be repaired because of dye seepage. The compres-
sor shaft seal should only be repaired after confirming the leakage with an electrical leak detector
(SST: J-41995).
• Always remove any remaining dye from the leakage area after repairs are completed to avoid a mis-
diagnosis during future service.
• Never allow dye to come into contact with painted body panels or interior components. Immediately
clean with the approved dye cleaner if dye is spilled. Fluorescent dye left on a surface for an
extended period of time cannot be removed.
• Never spray fluorescent dye cleaning agent on hot surfaces (engine exhaust manifold, etc.).
• Never use more than one refrigerant dye bottle [1/4 ounce (7.4 cc)] per A/C system.
• Leak detection dyes for HFC-134a (R-134a) and CFC-12 (R-12) A/C systems are different. Never use
HFC-134a (R-134a) leak detection dye in CFC-12 (R-12) A/C system or CFC-12 (R-12) leak detection
dye in HFC-134a (R-134a) A/C system, otherwise A/C system damage may result.
• The fluorescent properties of the dye remains for three or more years unless a compressor malfunc-
tion occurs.
IDENTIFICATION
NOTE:
Vehicles with factory installed fluorescent dye have a green label.
Vehicles without factory installed fluorescent dye have a blue label.
IDENTIFICATION LABEL FOR VEHICLE
Vehicles with factory installed fluorescent dye have an identification label on the front side of hood.
PREPARATION
HA-21
< PREPARATION >
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
PREPARATION
PREPARATION
Special Service Tool
INFOID:0000000009718625
The actual shapes of Kent-Moore tools may differ from those of special service tools illustrated here.
HFC-134a (R-134a) Service Tool and Equipment
• Never mix HFC-134a (R-134a) refrigerant and/or its specified lubricant with CFC-12 (R-12) refrigerant and/
or its lubricant.
• Separate and non-interchangeable service equipment must be used for handling each type of refrigerant/
lubricant.
• Refrigerant container fittings, service hose fittings and service equipment fittings (equipment that handles
refrigerant and/or lubricant) are different between CFC-12 (R-12) and HFC-134a (R-134a). This is to avoid
mixed use of the refrigerants/lubricant.
• Never use adapters that convert one size fitting to another. Refrigerant/lubricant contamination occurs and
compressor malfunction may result.
Tool number
(Kent-Moore No.)
Tool name
Description
KV99106200
(J-41260)
Pulley installer
Installing pulley
(ACR2005-NI)
ACR5 A/C Service Center
Function: Refrigerant recovery, recycling
and recharging
(J-41995)
Electrical leak detector
Power supply:
DC 12 V (Battery terminal)
S-NT235
WJIA0293E
AHA281A
HA-22
< PREPARATION >
PREPARATION
(J-43926)
Refrigerant dye leak detection
kit
Kit includes:
(J-42220)
UV lamp and UV safety goggles
(J-41459)
HFC-134a (R-134a) dye injector
Use with J-41447, 1/4 ounce
bottle
(J-41447)
HFC-134a (R-134a) fluorescent
leak detection dye
(Box of 24, 1/4 ounce bottles)
(J-43872)
Refrigerant dye cleaner
Power supply:
DC 12 V (Battery terminal)
(J-42220)
UV lamp and UV safety goggles
Power supply:
DC 12 V (Battery terminal)
For checking refrigerant leakage when flu-
orescent dye is equipped in A/C system
Includes:
UV lamp and UV safety goggles
(J-41447)
HFC-134a (R-134a) fluorescent
leak detection dye
(Box of 24, 1/4 ounce bottles)
Application:
For HFC-134a (R-134a) PAG oil
Container:
1/4 ounce (7.4 cc) bottle
(Includes self-adhesive dye identification
labels for affixing to vehicle after charging
system with dye.)
(J-41459)
HFC-134a (R-134a) dye injector
Use with J-41447, 1/4 ounce
bottle
For injecting 1/4 ounce of fluorescent leak
detection dye into A/C system
(J-43872)
Refrigerant dye cleaner
For cleaning dye spills
Tool number
(Kent-Moore No.)
Tool name
Description
ZHA200H
SHA438F
SHA439F
SHA440F
SHA441F
PREPARATION
HA-23
< PREPARATION >
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
(J-39183)
Manifold gauge set (with hoses
and couplers)
Identification:
• The gauge face indicates HFC-134a (R-
134a).
Fitting size: Thread size
• 1/2
″
-16 ACME
Service hoses
• High-pressure side hose
(J-39501-72)
• Low-pressure side hose
(J-39502-72)
• Utility hose
(J-39476-72)
Hose color:
• Low-pressure side hose: Blue with black
stripe
• High-pressure side hose: Red with black
stripe
• Utility hose: Yellow with black stripe or
green with black stripe
Hose fitting to gauge:
• 1/2
″
-16 ACME
Service couplers
• High-pressure side coupler
(J-39500-20)
• Low-pressure side coupler
(J-39500-24)
Hose fitting to service hose:
M14 x 1.5 fitting is optional or permanently
attached.
(J-39650)
Refrigerant weight scale
For measuring of refrigerant
Fitting size: Thread size
1/2
″
-16 ACME
(J-39649)
Vacuum pump
(Including the isolator valve)
Capacity:
• Air displacement: 4 CFM
• Micron rating: 20 microns
• Oil capacity: 482 g (17 oz)
Fitting size: Thread size
• 1/2
″
-16 ACME
Tool number
(Kent-Moore No.)
Tool name
Description
RJIA0196E
S-NT201
S-NT202
S-NT200
S-NT203