B27D1 START CUT RELAY OFF
SEC-263
< DTC/CIRCUIT DIAGNOSIS >
[WITHOUT INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
SEC
N
O
P
GI-44, "Intermittent Incident"
.
>> INSPECTION END
Component Inspection
INFOID:0000000010479769
1.
CHECK STARTER CONTROL RELAY
1.
Disconnect starter control relay.
2.
Check continuity between starter relay terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace starter control relay.
SEF497Y
starter control relay
Condition
Continuity
Terminal
12 V direct current supply between terminals
and
Existed
No current supply
Not existed
![](/vehicles/gon/ffua/inoowhem/uela.png)
SEC-264
< DTC/CIRCUIT DIAGNOSIS >
[WITHOUT INTELLIGENT KEY SYSTEM]
B27D2 START CUT RELAY ON
B27D2 START CUT RELAY ON
DTC Logic
INFOID:0000000010479770
DTC DETECTION LOGIC
POSSIBLE CAUSE
• Harness or connectors
(Starter control relay circuit is shorted)
• Starter control relay
• BCM
FAIL-SAFE
—
DTC CONFIRMATION PROCEDURE
1.
PERFORM DTC CONFIRMATION PROCEDURE
1.
Press push-button ignition switch under the following conditions and wait 1 second or more.
-
Selector lever: In the P position.
-
Brake pedal: Depressed.
2.
Check DTC in “Self Diagnostic Result” mode of “BCM” using CONSULT.
Is DTC detected?
YES
>> Refer to
SEC-264, "Diagnosis Procedure"
NO-1
>> To check malfunction symptom before repair: Refer to
GI-44, "Intermittent Incident"
.
NO-2
>> Confirmation after repair: INSPECTION END
Diagnosis Procedure
INFOID:0000000010479771
1.
CHECK STARTER CONTROL RELAY INPUT SIGNAL
Check voltage between BCM harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4
NO
>> GO TO 2
2.
CHECK STARTER CONTROL RELAY INPUT SIGNAL CIRCUIT
1.
Disconnect BCM connector and starter control relay connector.
2.
Check continuity between BCM harness connector and starter control relay harness connector.
3.
Check continuity between BCM harness connector and ground.
DTC
CONSULT screen items
DTC detecting condition
B27D2–00
START CUT RELAY ON
When BCM starter control relay is in OFF status, and when the starter relay/starter con-
trol relay status signal is (ON/ON)
(+)
(-)
Condition
Voltage
BCM
Connector
Terminal
E60
171
Ground
Engine cranking
0 - 0.5 V
Other than engine cranking
9 - 16 V
BCM
Starter control relay
Continuity
Connector
Terminal
Connector
Terminal
E60
171
F162
1
Existed
![](/vehicles/gon/ffua/inoowhem/ilever.png)
B27D2 START CUT RELAY ON
SEC-265
< DTC/CIRCUIT DIAGNOSIS >
[WITHOUT INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
SEC
N
O
P
Is the inspection result normal?
YES
>> GO TO 3
NO
>> Repair or replace harness.
3.
CHECK FUSE
Check that the following fuse is not blown
Is the fuse fusing?
YES
>> Replace the blown fuse after repairing the affected circuit if a fuse is blown.
NO
>> GO TO 6
4.
CHECK STARTER CONTROL RELAY OUTPUT SIGNAL
Check voltage between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> Replace IPDM E/R. Refer to
PCS-68, "Removal and Installation"
.
NO
>> GO TO 5
5.
CHECK STARTER CONTROL RELAY OUTPUT SIGNAL CIRCUIT
1.
Check continuity between IPDM E/R harness connector and starter control relay harness connector.
2.
Check continuity between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 6
NO
>> Repair or replace harness.
6.
CHECK STARTER CONTROL RELAY
Check starter control relay. Refer to
SEC-263, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 7
NO
>> Replace starter control relay.
7.
REPLACE BCM
BCM
Ground
Continuity
Connector
Terminal
E60
171
No Existed
Signal name
Fuse
Battery power supply
30A
L
(+)
(-)
Condition
Voltage
IPDM E/R
Connector
Terminal
F88
68
Ground
Other than engine
cranking
2 - 4 V
Engine cranking
6 - 16 V
IPDM E/R
Starter control relay
Continuity
Connector
Terminal
Connector
Terminal
F88
68
F162
3
Existed
IPDM E/R
Ground
Continuity
Connector
Terminal
F88
68
Not existed
![](/vehicles/gon/ffua/inoowhem/buth.png)
SEC-266
< DTC/CIRCUIT DIAGNOSIS >
[WITHOUT INTELLIGENT KEY SYSTEM]
B27D2 START CUT RELAY ON
Replace BCM.
BCS-135, "Removal and Installation"
.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> GO TO 8
8.
CHECK INTERMITTENT INCIDENT
GI-44, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000010479772
1.
CHECK STARTER CONTROL RELAY
1.
Disconnect starter control relay.
2.
Check continuity between starter relay terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace starter control relay.
SEF497Y
starter control relay
Condition
Continuity
Terminal
12 V direct current supply between terminals
and
Existed
No current supply
Not existed