Nissan Qashqai J11. Manual — part 1070
![](/vehicles/gon/ffua/forullalerus/lit.png)
HA-106
< SYSTEM DESCRIPTION >
[TYPE 3]
COMPONENT PARTS
SYSTEM DESCRIPTION
COMPONENT PARTS
Component Parts Location
INFOID:0000000010867293
Component Description
INFOID:0000000010867291
JMIIA3523ZZ
1.
Refrigerant pressure sensor
2.
Compressor
3.
Condenser
4.
Liquid tank
5.
Expansion valve
6.
Evaporator
A.
Built-in A/C unit assembly
Component
Description
Evaporator
The mist form liquid refrigerant transforms to gas by evaporation by the air conveyed from blower
motor. The air is cooled by the heat by evaporation.
Condenser
Cools refrigerant discharged from compressor, and transforms it to liquid refrigerant.
Compressor
Intakes, compresses, and discharges refrigerant, to circulate refrigerant inside the refrigerant cycle.
Refrigerant pressure sensor
HAC-19, "Refrigerant Pressure Sensor"
(AUTOMATIC AIR CONDITIONING SYSTEM) or
HAC-150, "Refrigerant Pressure Sensor"
(MANUAL AIR CINDITIONING SYSTEM).
Liquid tank
Eliminates foreign matter in refrigerant, and stores temporarily liquid refrigerant.
Expansion valve
Transforms high-pressure liquid refrigerant to mist form low-pressure liquid refrigerant by drawing
function.
![](/vehicles/gon/ffua/forullalerus/kitokspees.png)
DIAGNOSIS AND REPAIR WORKFLOW
HA-107
< BASIC INSPECTION >
[TYPE 3]
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
BASIC INSPECTION
DIAGNOSIS AND REPAIR WORKFLOW
Work Flow
INFOID:0000000010704937
OVERALL SEQUENCE
DETAILED FLOW
1.
INTERVIEW FOR MALFUNCTION
Interview the symptom to the customer.
NNIIA0143GB
![](/vehicles/gon/ffua/forullalerus/gizit.png)
HA-108
< BASIC INSPECTION >
[TYPE 3]
DIAGNOSIS AND REPAIR WORKFLOW
BASIC INSPECTION
DIAGNOSIS AND REPAIR WORKFLOW
Work Flow
INFOID:0000000010704937
OVERALL SEQUENCE
DETAILED FLOW
1.
INTERVIEW FOR MALFUNCTION
Interview the symptom to the customer.
NNIIA0143GB
![](/vehicles/gon/ffua/forullalerus/ferebando.png)
DIAGNOSIS AND REPAIR WORKFLOW
HA-109
< BASIC INSPECTION >
[TYPE 3]
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
>> GO TO 2.
2.
SYMPTOM CHECK
Check the symptom from the customer's information. Check that any symptom occurs other than the inter-
viewed symptom.
Insufficient cooling/heating>>GO TO 3.
Refrigerant leakage>>GO TO 6.
Noise >> GO TO 7.
3.
CONTROL SYSTEM DIAGNOSIS
Perform the system diagnosis for the A/C control system. Refer to
(AUTOMATOC AIR
CONDITIONING SYSTEM),
(MANUAL AIR CONDITIONING SYSTEM).
Is A/C control system normal?
YES
>> GO TO 4.
NO
>> GO TO 8.
4.
PERFORMANCE TEST
Perform the performance test. Check the operation of each part. Refer to
.
>> GO TO 5.
5.
TROUBLE DIAGNOSIS FOR UNUSUAL PRESSURE
Diagnose using a manifold gauge whenever system's high and/or low side pressure(s) is/are unusual. Specify
the malfunctioning part. Refer to
Low refrigerant charge>>GO TO 6.
Except above>>GO TO 8.
6.
CHECK REFRIGERANT FOR LEAKAGES
Check refrigerant for leakages. Specify the malfunctioning part. Refer to
>> GO TO 8.
7.
TROUBLE DIAGNOSIS FOR NOISE
Perform trouble diagnosis for noise. Specify the malfunctioning part. Refer to
.
>> GO TO 8.
8.
MALFUNCTION PART REPAIR
Repair or replace the malfunctioning part.
>> GO TO 9.
9.
REPAIR CHECK (OPERATION CHECK)
Check the operation of each part.
Does it operate normally?
YES
>> INSPECTION END
NO
>> GO TO 2.