Nissan Qashqai J11. Manual — part 726
![](/vehicles/gon/ffua/forullalerus/rub.png)
TCM
TM-479
< ECU DIAGNOSIS INFORMATION >
[CVT: RE0F10G]
C
E
F
G
H
I
J
K
L
M
A
B
TM
N
O
P
If the vehicle shows following behaviors including “poor acceleration”, a malfunction of the applicable system
is detected by TCM and the vehicle may be in a fail-safe mode. At this time, check the DTC code and perform
inspection and repair according to the malfunction diagnosis procedures.
Fail-safe function
DTC
Vehicle behavior
Conditions of vehicle
P062F
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
P0705
• Shift position indicator on combination meter is not dis-
played
• Selector shock is large
• Start is slow
• Acceleration is slow
• Lock-up is not performed
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
P0706
• Shift position indicator on combination meter is not dis-
played
• Selector shock is large
• Start is slow
• Acceleration is slow
• Lock-up is not performed
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
P0712
• Start is slow
• Acceleration is slow
Engine coolant temperature when engine start:
Temp.
≥
10
°
C (50
°
F)
• Selector shock is large
• Start is slow
• Acceleration is slow
Engine coolant temperature when engine start:
−
35
°
C (
−
31
°
F)
≤
Temp. < 10
°
C (50
°
F)
• Selector shock is large
• Start is slow
• Acceleration is slow
Engine coolant temperature when engine star:
Temp. <
−
35
°
C (
−
31
°
F)
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
P0713
• Start is slow
• Acceleration is slow
Engine coolant temperature when engine start:
Temp.
≥
10
°
C (50
°
F)
• Selector shock is large
• Start is slow
• Acceleration is slow
Engine coolant temperature when engine start:
−
35
°
C (
−
31
°
F)
≤
Temp. < 10
°
C (50
°
F)
• Selector shock is large
• Start is slow
• Acceleration is slow
Engine coolant temperature when engine star:
Temp. <
−
35
°
C (
−
31
°
F)
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
P0715
• Start is slow
• Acceleration is slow
• Lock-up is not performed
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
![](/vehicles/gon/ffua/forullalerus/chorifaveean.png)
TM-480
< ECU DIAGNOSIS INFORMATION >
[CVT: RE0F10G]
TCM
P0717
• Start is slow
• Acceleration is slow
• Lock-up is not performed
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
P0740
• Start is slow
• Acceleration is slow
• Lock-up is not performed
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
P0743
• Start is slow
• Acceleration is slow
• Lock-up is not performed
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
P0744
• Start is slow
• Acceleration is slow
• Lock-up is not performed
—
P0746
• Selector shock is large
• Start is slow
• Acceleration is slow
• Lock-up is not performed
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
P0776
• Selector shock is large
• Start is slow
• Acceleration is slow
• Lock-up is not performed
• Vehicle speed is not increased
When a malfunction occurs on the low oil pressure side
• Selector shock is large
• Start is slow
• Acceleration is slow
• Lock-up is not performed
When a malfunction occurs on the high oil pressure side
P0778
• Selector shock is large
• Start is slow
• Acceleration is slow
• Lock-up is not performed
—
P0779
• Selector shock is large
• Start is slow
• Acceleration is slow
• Lock-up is not performed
—
P0826
Manual mode is not activated
P0841
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
P0847
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
P0848
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
P084C
• Not changed from normal driving
P084D
• Not changed from normal driving
DTC
Vehicle behavior
Conditions of vehicle
![](/vehicles/gon/ffua/forullalerus/hbak.png)
TCM
TM-481
< ECU DIAGNOSIS INFORMATION >
[CVT: RE0F10G]
C
E
F
G
H
I
J
K
L
M
A
B
TM
N
O
P
P0863
• Selector shock is large
• Start is slow
• Acceleration is slow
• Lock-up is not performed
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
P0890
• Selector shock is large
• Start is slow
• Acceleration is slow
• Lock-up is not performed
• Vehicle speed is not increased
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
P0962
• Selector shock is large
• Start is slow
• Acceleration is slow
• Lock-up is not performed
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
P0963
• Selector shock is large
• Start is slow
• Acceleration is slow
• Lock-up is not performed
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
P0965
• Selector shock is large
• Start is slow
• Acceleration is slow
• Lock-up is not performed
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
When a malfunction occurs on the low oil pressure side
• Selector shock is large
• Lock-up is not performed
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
When a malfunction occurs on the high oil pressure side
P0966
• Selector shock is large
• Start is slow
• Acceleration is slow
• Lock-up is not performed
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
P0967
• Selector shock is large
• Start is slow
• Acceleration is slow
• Lock-up is not performed
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
P1586
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
P1588
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
DTC
Vehicle behavior
Conditions of vehicle
![](/vehicles/gon/ffua/forullalerus/cconot.png)
TM-482
< ECU DIAGNOSIS INFORMATION >
[CVT: RE0F10G]
TCM
P188E
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
• When the vehicle is in stop/start system operation and
the engine stops, restart the engine immediately
—
P188F
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
• When the vehicle is in stop/start system operation and
the engine stops, restart the engine immediately
—
P1890
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
• When the vehicle is in stop/start system operation and
the engine stops, restart the engine immediately
—
P2765
• Start is slow
• Acceleration is slow
• Lock-up is not performed
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
P2813
• Selector shock is large
• Start is slow
• Acceleration is slow
• Vehicle speed is not increased
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
When a malfunction occurs on the low oil pressure side
• Selector shock is large
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
When a malfunction occurs on the high oil pressure side
P2814
• Selector shock is large
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
P2815
• Selector shock is large
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
U0073
• Selector shock is large
• Start is slow
• Acceleration is slow
• Lock-up is not performed
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
U0100
• Selector shock is large
• Start is slow
• Acceleration is slow
• Lock-up is not performed
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
U0140
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
U0141
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay
—
DTC
Vehicle behavior
Conditions of vehicle
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст