Chery Tiggo 5 (T21). Service manual — part 346
31–
88
31
b. Remove 2 fixing screws (arrow) from the mode
damper adjustment mechanism set.
(Tightening torque: 2.5 ± 0.5 N·m)
c. Detach the mode damper adjustment mechanism set from the evaporator tank assembly carefully.
19.Remove the temperature/face/defroster/foot damper set.
a. Detach the A/C wire harness assembly (arrow) from
the evaporator tank assembly.
b. Remove 2 fixing screws (arrow) from the front part of
evaporator tank assembly.
(Tightening torque: 2.5 ± 0.5 N·m)
c. Remove the fixing screw (arrow) from the upper part
of evaporator tank assembly.
(Tightening torque: 2.5 ± 0.5 N·m)
RT21310630
RT21310640
RT21310650
RT21310660
31–
89
31
d. Remove the fixing screw (arrow) from the lower part of
evaporator tank assembly.
(Tightening torque: 2.5 ± 0.5 N·m)
e. Detach the fixing clips, separate the evaporator case,
and remove the temperature damper set.
f. Remove the face damper set.
g. Remove the defroster damper set.
RT21310670
RT21310680
RT21310690
RT21310700
31–
90
31
h. Remove the foot damper set.
Inspection
1. Check the evaporator temperature sensor.
a. Using the ohm band of digital multimeter, measure the
resistance of evaporator temperature sensor
according to the table below.
Standard Resistance
RT21310710
1 2
-
+
RT21310720
Multimeter
Connection
Temperature
(°C)
Specified
Condition
(Ω)
Temperature
(°C)
Specified
Condition
(Ω)
Temperature
(°C)
Specified
Condition
(Ω)
Terminal 1 -
Terminal 2
-40
45636
-8
8916
24
2294
Terminal 1 -
Terminal 2
-39
43408
-7
8516
25
2200
Terminal 1 -
Terminal 2
-38
41180
-6
8116
26
2125
Terminal 1 -
Terminal 2
-37
38953
-5
7716
27
2050
Terminal 1 -
Terminal 2
-36
36725
-4
7412
28
1975
Terminal 1 -
Terminal 2
-35
34498
-3
7107
29
1900
Terminal 1 -
Terminal 2
-34
32864
-2
6803
30
1825
Terminal 1 -
Terminal 2
-33
31230
-1
6498
31
1764
Terminal 1 -
Terminal 2
-32
29596
0
6194
32
1704
Terminal 1 -
Terminal 2
-31
27962
1
5922
33
1643
31–
91
31
Terminal 1 -
Terminal 2
-30
26328
2
5663
34
1583
Terminal 1 -
Terminal 2
-29
25117
3
5418
35
1522
Terminal 1 -
Terminal 2
-28
23906
4
5185
36
1473
Terminal 1 -
Terminal 2
-27
22695
5
4963
37
1424
Terminal 1 -
Terminal 2
-26
21484
6
4752
38
1375
Terminal 1 -
Terminal 2
-25
20273
7
4552
39
1326
Terminal 1 -
Terminal 2
-24
19367
8
4361
40
1277
Terminal 1 -
Terminal 2
-23
18461
9
4180
41
1237
Terminal 1 -
Terminal 2
-22
17554
10
4007
42
1197
Terminal 1 -
Terminal 2
-21
16648
11
3857
43
1156
Terminal 1 -
Terminal 2
-20
15742
12
3708
44
1116
Terminal 1 -
Terminal 2
-19
15058
13
3558
45
1076
Terminal 1 -
Terminal 2
-18
14374
14
3408
46
1043
Terminal 1 -
Terminal 2
-17
13689
15
3259
47
1010
Terminal 1 -
Terminal 2
-16
13005
16
3141
48
978
Terminal 1 -
Terminal 2
-15
12321
17
3023
49
945
Terminal 1 -
Terminal 2
-14
11800
18
2905
50
912
Terminal 1 -
Terminal 2
-13
11279
19
2787
51
885
Terminal 1 -
Terminal 2
-12
10758
20
2669
52
858
Terminal 1 -
Terminal 2
-11
10237
21
2575
53
830
Terminal 1 -
Terminal 2
-10
9716
22
2481
54
803
Multimeter
Connection
Temperature
(°C)
Specified
Condition
(Ω)
Temperature
(°C)
Specified
Condition
(Ω)
Temperature
(°C)
Specified
Condition
(Ω)