Nissan Sentra. Instruction — part 249
DLK-112
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
TRUNK LID OPENER ACTUATOR
Is the inspection normal?
YES
>> Replace trunk lid opener assembly.
NO
>> Repair or replace harness.
Trunk lid opener assembly
Ground
Continuity
Connector
Terminal
B59
2
Yes
TRUNK LID OPENER SWITCH
DLK-113
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
TRUNK LID OPENER SWITCH
Component Function Check
INFOID:0000000009756418
1.
CHECK FUNCTION
1. Select TRUNK of BCM using CONSULT.
2. Select TR/BD OPEN SW in DATA MONITOR mode.
3. Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Trunk lid opener switch is OK.
NO
>> Refer to
DLK-113, "Diagnosis Procedure"
Diagnosis Procedure
INFOID:0000000009756419
Regarding Wiring Diagram information, refer to
.
1.
CHECK TRUNK LID OPENER INPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect trunk lid opener switch connector.
3. Check signal between trunk lid opener switch harness connector and ground using oscilloscope.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK TRUNK LID OPENER SWITCH CIRCUIT
1. Disconnect BCM connector.
2. Check continuity between BCM harness connector and trunk lid opener switch harness connector.
3. Check continuity between BCM harness connector and ground.
Monitor item
Condition
Status
TR/BD OPEN SW
Trunk lid opener switch
Pressed
On
Released
Off
(+)
(–)
Signal
(Reference value)
Trunk lid opener switch
Connector
Terminal
M15
1
Ground
JPMIA0012GB
BCM
Trunk lid opener switch
Continuity
Connector
Terminal
Connector
Terminal
M84
30
M15
1
Yes
BCM
Ground
Continuity
Connector
Terminal
M84
30
No
DLK-114
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
TRUNK LID OPENER SWITCH
Is the inspection result normal?
YES
>> Replace BCM. Refer to
BCS-73, "Removal and Installation"
NO
>> Repair or replace harness.
3.
CHECK TRUNK LID OPENER SWITCH GROUND CIRCUIT
Check continuity between trunk lid opener switch harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK TRUNK LID OPENER SWITCH
DLK-113, "Component Function Check"
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace trunk lid opener switch.
5.
CHECK INTERMITTENT INCIDENT
GI-39, "Intermittent Incident"
>> Inspection End.
Component Inspection
INFOID:0000000009756420
1.
CHECK TRUNK LID OPENER SWITCH
1. Turn ignition switch OFF.
2. Disconnect trunk lid opener switch connector.
3. Check continuity between trunk lid opener switch terminals.
Is the inspection result normal?
YES
>> Inspection End.
NO
>> Replace trunk lid opener switch.
Trunk lid opener switch
Ground
Continuity
Connector
Terminal
M15
2
Yes
Trunk lid opener switch
Condition
Continuity
Terminal
1
2
Trunk lid opener switch
Pressed
Yes
Release
No
TRUNK LAMP SWITCH
DLK-115
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
TRUNK LAMP SWITCH
Description
INFOID:0000000009756421
Detects trunk open/close condition.
Component Function Check
INFOID:0000000009756422
1.
CHECK FUNCTION
With CONSULT
Check TRNK/HAT MNTR in Data Monitor mode with CONSULT.
Is the inspection result normal?
YES
>> Trunk room lamp switch is OK.
NO
>> Refer to
DLK-115, "Diagnosis Procedure"
Diagnosis Procedure
INFOID:0000000009756423
Regarding Wiring Diagram information, refer to
.
1.
CHECK TRUNK LID SWITCH INPUT SIGNAL
1. Turn ignition switch OFF.
2. Check voltage between BCM connector and ground.
Is the inspection result normal?
YES
>> GO TO 6
NO
>> GO TO 2
2.
CHECK TRUNK ROOM LAMP SWITCH CIRCUIT
1. Disconnect BCM and trunk lid opener assembly connector.
2. Check continuity between BCM connector and trunk lid opener assembly connector.
3. Check continuity between BCM connector and ground.
Monitor item
Condition
TRNK/HAT MNTR
OPEN
: ON
CLOSE
: OFF
Terminals
Trunk
condition
Voltage (V)
(Approx.)
(+)
(–)
BCM
connector
Terminal
B24
103
Ground
OPEN
0
CLOSE
7.0 - 8.0V
PKIB4960J
BCM connector
Terminal
Trunk lid opener as-
sembly connector
Terminal
Continuity
B24
103
B59
1
Yes