Subaru Impreza 3 / Impreza WRX / Impreza WRX STI. Service manual — part 368
GD(H4DOTC)-224
Diagnostic Trouble Code (DTC) Detecting Criteria
GENERAL DESCRIPTION
5. DIAGNOSTIC METHOD
• Abnormality Judgment
At the main IC, check the sent signal at each timing which occurs immediately after the tumble generator
valve output is set to ON → OFF, and judge open NG when the open NG signal is sent 96 ms × 20 time(s)
in a row.
Time Needed for Diagnosis: 96 ms × 20 time(s)
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
• Normality Judgment
Judge as OK and clear the NG when the OK signal is sent.
Time Needed for Diagnosis: Less than 1 second
Judgment Value
Malfunction Criteria
Threshold Value
Open NG signal input
Low
Judgment Value
Malfunction Criteria
Threshold Value
Open NG signal input
High
GD(H4DOTC)-225
Diagnostic Trouble Code (DTC) Detecting Criteria
GENERAL DESCRIPTION
EF:DTC P2012 INTAKE MANIFOLD RUNNER CONTROL CIRCUIT LOW (BANK 2)
1. OUTLINE OF DIAGNOSIS
Detect the open or short circuit of tumble generator valve motor.
Judge as NG when the overcurrent signal is sent from IC after tumble generator valve driving IC diagnosis.
2. COMPONENT DESCRIPTION
3. ENABLE CONDITIONS
4. GENERAL DRIVING CYCLE
Always perform the diagnosis continuously.
5. DIAGNOSTIC METHOD
• Abnormality Judgment
At the main IC, check the sent signal at each timing which occurs just before the tumble generator valve out-
put is set to ON → OFF, and judge open NG when the open NG signal is sent 96 ms × 10 time(s) in a row.
Time Needed for Diagnosis: 96 ms × 10 time(s)
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
• Normality Judgment
Judge as OK and clear the NG when the OK signal is sent.
Time Needed for Diagnosis: Less than 1 second
(1)
Engine control module (ECM)
(2)
Tumble generator valve
(3)
Battery
Secondary Parameters
Enable Conditions
Battery voltage
≥ 10.9 V
Judgment Value
Malfunction Criteria
Threshold Value
Overcurrent NG signal input
Low
Judgment Value
Malfunction Criteria
Threshold Value
Overcurrent NG signal input
High
EN-01789
E
E
(3)
M
(2)
(1)
GD(H4DOTC)-226
Diagnostic Trouble Code (DTC) Detecting Criteria
GENERAL DESCRIPTION
EG:DTC P2016 TUMBLE GENERATED VALVE POSITION SENSOR 1 CIRCUIT
LOW
1. OUTLINE OF DIAGNOSIS
Detect open or short circuit of tumble generator valve position sensor.
Judge as NG if out of specification.
2. COMPONENT DESCRIPTION
3. ENABLE CONDITIONS
4. GENERAL DRIVING CYCLE
Always perform the diagnosis continuously.
(1)
Rotor
(3)
Voltage (V)
(4)
Tumble generator valve opening
(°)
(2)
Return spring
Secondary Parameters
Enable Conditions
None
EN-01768
(3)
(4)
(1)
(2)
GD(H4DOTC)-227
Diagnostic Trouble Code (DTC) Detecting Criteria
GENERAL DESCRIPTION
5. DIAGNOSTIC METHOD
• Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Time Needed for Diagnosis: 500 ms
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
• Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more
than the predetermined time.
Time Needed for Diagnosis: Less than 1 second
Judgment Value
Malfunction Criteria
Threshold Value
Output voltage
< 0.264 V
Judgment Value
Malfunction Criteria
Threshold Value
Output voltage
≥ 0.264 V
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.