Subaru Legacy IV (2008 year). Service manual — part 468
IN(H6DO)-7
Air Intake Chamber
INTAKE (INDUCTION)
4. Air Intake Chamber
A: REMOVAL
1) Remove the collector cover.
2) Loosen the clamp (A) which connects air intake
chamber to throttle body.
3) Loosen the clamp (B) which connects intake
boot to air intake chamber.
4) Remove the bolt (C) which secures air intake
chamber to the stay.
5) Disconnect the blow-by hoses, then remove the
air intake chamber.
B: INSTALLATION
Install in the reverse order of removal.
Tightening torque:
Clamp (A), (B)
3 N·m (0.3 kgf-m, 2.2 ft-lb)
Bolt (C)
6.5 N·m (0.7 kgf-m, 4.8 ft-lb)
C: INSPECTION
1) Check for cracks or loose connections.
2) Check that no foreign matter is mixed in air in-
take chamber.
(A)
IN-02095
(C)
(C)
(B)
(A)
IN-02095
(C)
(C)
(B)
IN(H6DO)-8
Air Intake Duct
INTAKE (INDUCTION)
5. Air Intake Duct
A: REMOVAL
1) Remove the clip which installs the air intake duct
on the front side of body.
2) Remove the air intake duct.
B: INSTALLATION
Install in the reverse order of removal.
C: INSPECTION
1) Check for cracks or loose connections.
2) Check that no foreign matter is mixed in air in-
take duct.
IN-02013
IN(H6DO)-9
Resonator Chamber
INTAKE (INDUCTION)
6. Resonator Chamber
A: REMOVAL
The resonator chamber and air cleaner case are in-
tegrated into one unit; therefore, refer to “Air Clean-
er Case” for removal procedure. <Ref. to
IN(H6DO)-5, REMOVAL, Air Cleaner Case.>
B: INSTALLATION
The resonator chamber and air cleaner case are in-
tegrated into one unit; therefore, refer to “Air Clean-
er Case” for installation procedure. <Ref. to
IN(H6DO)-6, INSTALLATION, Air Cleaner Case.>
C: INSPECTION
Check for cracks or loose connections.
IN(H6DO)-10
Resonator Chamber
INTAKE (INDUCTION)
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.