Subaru Legacy IV (2008 year). Service manual — part 608
GD(H6DO)-52
Diagnostic Trouble Code (DTC) Detecting Criteria
GENERAL DESCRIPTION
5. DIAGNOSTIC METHOD
• Abnormality Judgement
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Time Needed for Diagnosis: 1000 ms
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
• Normality Judgement
Judge as OK and clear the NG if the continuous time while the following conditions are established is more
than the predetermined time.
Time Needed for Diagnosis: Less than 1 second
Judgement Value
Malfunction criteria
Threshold value
Input voltage
< 1.800 V
or
Input current
< –0.005 A
Judgement Value
Malfunction criteria
Threshold value
Input voltage
t 1.800 V
Input current
t –0.005 A
GD(H6DO)-53
Diagnostic Trouble Code (DTC) Detecting Criteria
GENERAL DESCRIPTION
AL:DTC P0132 O2 SENSOR CIRCUIT HIGH VOLTAGE (BANK 1 SENSOR 1)
1. OUTLINE OF DIAGNOSIS
Detect the open or short circuit of sensor.
Judge as NG when the element applied voltage is out of range, or the element current is out of range.
2. COMPONENT DESCRIPTION
3. ENABLE CONDITION
4. GENERAL DRIVING CYCLE
Always perform the diagnosis continuously.
(A)
Electromotive force
(C)
Lean
(D)
Rich
(B)
Air fuel ratio
(1)
Atmosphere
(3)
ZrO
2
(4)
Ceramic heater
(2)
Exhaust gas
Secondary Parameters
Enable Conditions
Battery voltage
t 10.9 V
(1)
(2)
(4)
(2)
(3)
EN-01693
(C)
(B)
(D)
(A)
GD(H6DO)-54
Diagnostic Trouble Code (DTC) Detecting Criteria
GENERAL DESCRIPTION
5. DIAGNOSTIC METHOD
• Abnormality Judgement
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Time Needed for Diagnosis: 1000 ms
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
• Normality Judgement
Judge as OK and clear the NG if the continuous time while the following conditions are established is more
than the predetermined time.
Time Needed for Diagnosis: Less than 1 second
Judgement Value
Malfunction criteria
Threshold value
Input voltage
> 3.800 V
or
Input current
> 0.005 A
Judgement Value
Malfunction criteria
Threshold value
Input voltage
d 3.800 V
Input current
d 0.005 A
GD(H6DO)-55
Diagnostic Trouble Code (DTC) Detecting Criteria
GENERAL DESCRIPTION
AM:DTC P0133 O2 SENSOR CIRCUIT SLOW RESPONSE (BANK 1 SENSOR 1)
1. OUTLINE OF DIAGNOSIS
Detect the slow response of front oxygen (A/F) sensor.
Front oxygen (A/F) sensor cover has some ventilation holes for exhaust gas. Clogged ventilation holes are
diagnosed.
When the holes are clogged, the A/F output variation becomes slow comparing with the actual A/F variation
because oxygen which reaches the zirconia layer is insufficient. Therefore, if the sensor cover holes are
clogged, the rich to lean judgment in the ECM is delayed when the actual change from rich to lean occurs.
Judge as NG when the actual movement in comparison to the ECM control amount is slow.
(1)
Cover
(2)
Zirconia
(3)
Clogging
EN-01694
(1)
(2)
(3)