Opel Frontera UBS. Service manual — part 770
8D – 510 WIRING SYSTEM
4. Sliding Mechanism Does Not Operate
•
IS TILT & SLIDE SWITCH NORMAL?
YES
•
IS SLIDE MOTOR NORMAL?
REPAIR OR REPLACE THE TILT &
SLIDE SWITCH
NO
YES
REPAIR A POOR CONNECTION AT THE CONNECTORS OR AN
OPEN CIRCUIT BETWEEN 5 T-1 AND 1 T-7 , 10 T-1 AND
2 T-7 OR 2 T-2
REPAIR OR REPLACE THE SLIDE
MOTOR
NO
5. Reclining Mechanism Does Not Operate
•
IS RECLINER SWITCH NORMAL?
YES
•
IS RECLINER MOTOR NORMAL?
REPAIR OR REPLACE THE RECLINER
SWITCH
NO
YES
REPAIR A POOR CONNECTION AT THE CONNECTORS 3 T-11 ,
6 T-11 , 2 T-11 , 5 T-11 AND 4 T-11
REPAIR OR REPLACE THE RECLINER
MOTOR
NO
WIRING SYSTEM 8D – 511
Passenger Seat
1. Power Seat Does Not Operate At Any Direction
•
IS THE CIRCUIT BREAKER C/B-2 (30A) NORMAL?
YES
•
IS THE GROUND SECURELY GROUNDED?
REPLACE THE CIRCUIT BREAKER
NO
YES
GROUND IT SECURELY
NO
YES
REPAIR A POOR CONNECTION AT THE CONNECTORS OR AN
OPEN CIRCUIT 2 T-9 AND THE GROUND
REPAIR A POOR CONNECTION AT THE
CONNECTORS OR AN OPEN CIRCUIT
BETWEEN CIRCUIT BREAKER AND 1 T-9
NO
•
IS THE BATTERY VOLTAGE APPLIED BETWEEN 1 T-9
AND GROUND?
8D – 512 WIRING SYSTEM
2. Sliding Mechanism Does Not Operate
•
IS SLIDE SWITCH NORMAL?
YES
•
IS SLIDE MOTOR NORMAL?
REPAIR OR REPLACE THE SLIDE
SWITCH
NO
YES
REPAIR A POOR CONNECTION AT THE CONNECTORS 1 T-13
AND 2 T-13
REPAIR OR REPLACE THE SLIDE
MOTOR
NO
3. Reclining Mechanism Does Not Operate
•
IS RECLINER SWITCH NORMAL?
YES
•
IS RECLINER MOTOR NORMAL?
REPAIR OR REPLACE THE RECLINER
SWITCH
NO
YES
REPAIR A POOR CONNECTION AT THE CONNECTORS 5 T-12 ,
3 T-12 , 6 T-12 , 2 T-12 AND 4 T-12
REPAIR OR REPLACE THE RECLINER
MOTOR
NO
WIRING SYSTEM 8D – 513
Shift On The Fly System